The AirTAC GFR200C06LJF3WTK AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LJF3WTK is an AirTAC GFR200 size filter regulator: filtration and pressure regulation combined in one body. It removes water and particulate from compressed air through a 5 um element (the fine grade, code W, versus the 40 um standard), then regulates downstream pressure with the low-pressure type regulator. The 06 port position decodes to a 1/8 in NPT thread, and the fitted square gauge reads in bar. A reverse/check valve (code K) is fitted, the differential-pressure drain removes collected condensate, and no mounting bracket is included in this configuration.
This is a genuine AirTAC part in the GFR series, which spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in and PT, G or NPT threads. Max working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published by AirTAC as curves rather than a single rated figure, so ask us to confirm flow and datasheet figures for your application on request.
| Model | GFR200C06LJF3WTK AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a fixture circuit where actuators must not see full line pressure, this low-pressure type filter regulator cleans the air to 5 um and holds a reduced setting, with the check valve holding the set circuit if upstream supply dips.
Feeding cylinders and grippers on a packaging line, the unit strips water and fine particulate before regulation, while the reverse/check valve prevents backflow through the branch when adjacent stations vent.
For bench instruments and test rigs fed from a shop-air drop, the 5 um element protects sensitive components and the low-pressure regulator gives a gentle, stable supply at the 1/8 in NPT connection.
The GFR200 is the smallest size step in the GFR range, with a 1/8 in port here - step up to GFR300/400/600 if your line needs larger ports and more flow. This unit carries the W code, so it filters to 5 um; choose the blank code instead if 40 um standard filtration is sufficient. The differential-pressure drain (the blank drain code) bleeds condensate automatically as flow passes the unit; automatic (A) or manual (M) drains are the other catalogue choices. The square gauge is fitted and scaled in bar; external round gauges and MPa or psi scales are options. Thread is NPT here, with PT standard and G (BSPP) available to order, and the J code means no mounting bracket is included.
Because AirTAC publishes flow only as curves and not as a single rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number. Tell us your application and we will confirm the flow and datasheet figures for this 1/8 in, size 200 unit on request before you order.
The W code selects the 5 um fine grade instead of the 40 um standard element, for applications that need cleaner air. The K code fits a reverse/check valve, which blocks backflow through the unit. Both are catalogue options on the GFR filter regulator, and this configuration carries both.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.