The AirTAC GFR200C06LJNWT AirTAC Low-Pressure Filter Regulator 1/8 NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR series combines water and particulate filtration with pressure regulation in a single body. This GFR200C06LJNWT is the size 200 unit with a 1/8 in NPT port, the low-pressure regulator type, a 5 um filter element (code W), a differential-pressure drain and a metal bowl. It is supplied without a gauge, without a reverse/check valve and without a mounting bracket.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, PT as the standard thread and G or NPT as order options, plus choices of drain type, filter grade and gauge. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.
| Model | GFR200C06LJNWT AirTAC Low-Pressure Filter Regulator 1/8 NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Conditioning the air feed to small grippers and cylinders on an assembly cell, where the low-pressure regulator holds a gentle working pressure and the 5 um element protects seals from particulate.
Filtering and regulating the compressed air feeding laboratory analyser enclosures and sample-handling actuators, with the differential-pressure drain shedding condensate as air passes through.
Supplying filtered, regulated pilot air to sorting and divert gates on a bottling or packaging conveyor, keeping control valves downstream free of water and debris.
Choose the size and port against the air demand of the circuit: this unit is size 200 with a 1/8 in NPT port, the smallest step in the GFR range, which runs up to size 600 and 1 in ports. The 5 um element (code W) suits points of use that need finer filtration than the 40 um standard. The differential-pressure drain sheds condensate automatically as air passes, with no drain fitting to operate. The low-pressure regulator type (code L) is selected where the circuit runs below standard regulator settings; its exact adjustment range is not published, so confirm it with us. No gauge is fitted (code N) and no bracket is included (code J); gauges and brackets are available on other variants in the range. Thread options are PT as standard with G and NPT to order - this unit carries NPT. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR performance as flow curves rather than a single rated figure, so we do not quote a number here. Send us your application's air demand and we will confirm from the datasheet whether the GFR200 at 1/8 in NPT is correctly sized.
The W code fits the 5 um element instead of the 40 um standard, for points of use that need finer filtration. The L code selects the low-pressure regulator type, intended for circuits that run below standard regulator settings; its exact adjustment range is not published, so confirm it with us before ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.