The AirTAC GFR200C06MC1TK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MC1TK is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a 1/8 in NPT port, a manual drain bowl, standard 40 um filtration, and a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi). A round pressure gauge with MPa scale is fitted, a reverse/check valve is built in, and a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The bowl on this size is polycarbonate (PC).
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of PT, G or NPT thread, manual, automatic or differential-pressure drains, 40 um or 5 um (W) filtration, gauge scale options, and a low-pressure regulator type. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | GFR200C06MC1TK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use conditioning for the solenoid valve manifold on a carton-sealing or wrapping machine: the GFR200C06MC1TK filters water and debris out of the shop air and holds a steady regulated pressure so valve shifting stays consistent, with the check valve holding the downstream circuit if the main supply dips.
Feeding the clamp cylinders on a machining-centre fixture: clean, regulated air at a set pressure keeps clamping force repeatable part after part, and the fitted MPa gauge lets the operator verify set pressure at a glance.
Supplying the air cylinders that push bottles between conveyor lanes in a bottling plant: the 40 um element protects the small directional valves from grit and condensed water, and the regulator sets the gate speed pressure independently of the plant header.
Size and port set the capacity of the unit: this is a size 200 with a 1/8 in NPT port, the smallest step in the GFR range, so step up to 300, 400 or 600 if your line needs more flow. The manual drain on this model means the bowl must be drained by hand, which suits intermittent or attended duty; automatic or differential-pressure drains are available if the unit will run unattended. Filtration is the standard 40 um grade; specify the W code for 5 um if finer protection is needed. The fitted round gauge reads in MPa, with psi and bar scales available as options, and the built-in check valve holds downstream pressure if the upstream supply drops. Thread is NPT here, with PT (standard) and G as order options, and a bracket is included.
Because AirTAC publishes flow as curves rather than a single rated figure, we do not quote a flow number here. Send us your application details and we will confirm the datasheet and correct sizing before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as performance curves rather than a single rated figure, so we do not quote a flow number for this model. Tell us your application and we will confirm the datasheet and check the sizing against your required flow on request before you order.
The M code in GFR200C06MC1TK specifies a manual drain bowl, meaning condensate is drained by hand, which suits attended or intermittent duty. The same unit is available with an automatic drain (code A) or the default differential-pressure drain, and the regulation range differs slightly by drain type: 0.05-0.9 MPa (7-130 psi) with manual drain versus 0.15-0.9 MPa (20-130 psi) with automatic or differential-pressure drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.