The AirTAC GFR200C06MC1WTK AirTAC Filter Regulator NPT1/8 5um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MC1WTK is a filter regulator: one body that removes water and particulate from compressed air and then regulates downstream pressure. This 200-size unit has a 1/8 in NPT port, a fine 5 um filtration element (the W grade, tighter than the 40 um standard), a manual drain on the bowl, a round pressure gauge with MPa scale, and a built-in check valve that holds downstream pressure when the upstream supply is lost. The standard regulator covers an adjustment range of 0.05-0.9 MPa (7-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -5 to 70 C (non-freezing). The bowl on this size is polycarbonate.
This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600 with larger ports and higher flow at each step, plus options including 5 um or 40 um filtration, manual, automatic or differential-pressure drains, square or round gauges with MPa, psi or bar scales, a low-pressure regulator type, and G, NPT or PT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06MC1WTK AirTAC Filter Regulator NPT1/8 5um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding clean, regulated air to grippers and small actuator circuits on a robot cell, where the 5 um element protects fine valve internals and the check valve holds the circuit if the plant air drops.
Regulating supply pressure to divert and clamp cylinders on a packaging conveyor, with the round MPa gauge giving operators a clear setpoint and the manual drain for end-of-shift water removal.
A compact filter-regulator at a bench or machine tool air drop, tightening the port to 1/8 in NPT for small tool circuits while the 5 um element keeps moisture and debris out of air tools.
Size up by port and flow: the 200 body with a 1/8 in port suits compact supply points, while 300, 400 and 600 steps carry progressively more flow - we can confirm the curve against your demand. Filtration grade is a real choice: 40 um is the standard element, and the W code on this model selects the finer 5 um element for sensitive downstream equipment. Drain type matters: this unit has a manual drain you operate yourself, while automatic and differential-pressure drains are available on other codes. Gauges come as an embedded square gauge or an external round gauge, in MPa, psi or bar scales; this code carries the round MPa gauge. Thread is a decodable option: PT is the standard, with G (BSPP) and NPT as order options - this model is NPT. A bracket is included on this code, and the K code adds a check valve.
Because flow is published as curves and not a single rated figure, ask us to confirm sizing against your application before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your port size and air demand and we will confirm the flow figures from the datasheet for this exact model on request.
The M in the code selects a manual drain - you open it yourself to release collected water, which suits points that are checked regularly; automatic and differential-pressure drains are available on other codes. The W selects the 5 um filtration element instead of the 40 um standard, for finer protection of downstream equipment. Both are order-time choices, so pick the code that matches your maintenance routine.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.