The AirTAC GFR200C06MC2WK AirTAC Filter Regulator PT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MC2WK is an AirTAC GFR200 filter regulator: one body that removes water and particulate down to 5 um and regulates downstream pressure. It is piped at PT 1/8 in with a polycarbonate bowl fitted with a manual drain, so condensate is emptied by hand as part of routine maintenance. The built-in check valve (code K) lets downstream air hold when the upstream supply is shut off, and the round pressure gauge reads in psi so the setting can be checked at a glance. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, a choice of manual, automatic or differential-pressure drains, 40 um or 5 um filtration, gauge styles and scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06MC2WK AirTAC Filter Regulator PT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding clamp and swing cylinders on a machining fixture, where the 5 um element keeps scale and pipe debris out of the clamping valves and the regulator holds a steady clamp pressure. The check valve keeps the clamp from releasing if the plant air drops.
Supplying the heat-seal and cut-off cylinders on a bagging or wrapping line, where clean, dry, regulated air keeps seal timing consistent through the shift. The manual drain is emptied during scheduled line cleaning.
Regulating the supply to vacuum-generator and gripper circuits on a case palletizer, where the psi gauge lets the technician set and verify grip pressure at the drop and the 5 um element protects the ejector valves.
Start with the port step: this unit is the size 200 body at 1/8 in PT; if your line needs more flow, step up through GFR300, GFR400 or GFR600 rather than throttling a small unit hard. This code carries the 5 um element (the W option) instead of the 40 um standard, manual drain instead of automatic or differential-pressure, and a round external gauge on the psi scale; square embedded gauges and MPa or bar scales are also available in the series. The check valve (K) is fitted, and the mounting bracket is included. Thread is PT as standard, with G (BSPP) and NPT as order options. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a flow figure for this unit. Send us your inlet pressure, set pressure and expected air demand, and we will confirm the sizing against the datasheet curves on request before you order.
The M in the code selects the manual drain: condensate collected in the polycarbonate bowl is released by hand rather than automatically. On this configuration the manual drain also allows the widest regulator setting range, 0.05-0.9 MPa (7-130 psi). Plan to drain the bowl during routine checks, or specify the automatic or differential-pressure drain version if the unit is mounted where it cannot easily be reached.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.