The AirTAC GFR200C06MF2 AirTAC Filter Regulator 1/8 in PT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MF2 is a size-200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a PT1/8 (1/8 in) port with PT thread as standard, a manual drain bowl, a 40 um filter element, an embedded square gauge scaled in psi, and a mounting bracket. The standard regulator covers 0.05-0.9 MPa (7-130 psi) with this manual-drain version, maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this size is polycarbonate (PC).
This is a genuine AirTAC part. The GFR family is also available in sizes 300, 400 and 600 with larger ports, a choice of differential-pressure, automatic or manual drain, an optional 5 um (code W) element, alternative gauge scales, G or NPT thread options, and a no-bracket variant. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR200C06MF2 AirTAC Filter Regulator 1/8 in PT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Clean, regulated air to the clamping cylinders and tool-change actuators on a CNC machining centre, with the psi gauge letting operators set and check clamp pressure at the machine.
Point-of-use air preparation for the pneumatic pushers and stopper cylinders on a carton packaging conveyor, where the manual drain suits a station attended during changeovers.
Supplying filtered, regulated air to diaphragm-actuated control valves on a process skid, keeping water and pipe scale out of the positioner and holding a stable set pressure.
Start with the port step: this unit is 1/8 in PT, and the GFR family steps up through sizes 300, 400 and 600 for larger ports and higher air demand - match the size to the flow your circuit needs. Choose the drain to suit access: manual drain (this model) needs periodic draining by hand, automatic drain handles it unattended, and differential-pressure drain is the catalogue default. Filter grade is 40 um standard; specify 5 um (code W) where finer filtration is required. The embedded square gauge is standard with MPa, psi or bar scales - this unit carries the psi scale - and an external round gauge is optional. Thread is PT as standard with G (BSPP) and NPT as order options, and the bracket can be omitted (code J) if not needed. Flow for this family is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and we will confirm the flow data from the datasheet and check the sizing with you before you order.
The M in the code specifies a manual drain: collected water is emptied from the polycarbonate bowl by hand, so the unit should be mounted where the bowl is accessible and drained as part of routine maintenance. If you prefer unattended draining, the same family is available with automatic or differential-pressure drain instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.