The AirTAC GFR200C06MF2TK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MF2TK is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a 1/8 in NPT port, a 40 um filter element, a manual drain on the bowl, and a built-in reverse/check valve that holds downstream pressure when the upstream supply is lost. The embedded square gauge reads in psi, and a mounting bracket is included. The standard regulator covers a set-point range of 0.05-0.9 MPa (7-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi), and the unit operates from -5 to 70 C in non-freezing conditions.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in. Across the series you can order manual, automatic or differential-pressure drains, a 5 um element (code W) instead of the 40 um standard, psi, MPa or bar gauge scales, G or NPT threads in place of the PT standard, and low-pressure or check-valve variants. Flow figures for this series are published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200C06MF2TK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, regulated air to a small machining center's tool-clamp and coolant-nozzle circuits, with the psi gauge letting operators verify set pressure at the machine and the check valve holding clamp pressure during a supply dip.
Conditions the air feeding the cylinders and grippers on a carton-sealing or labeling machine, removing water and pipe scale at 40 um and holding a stable regulated pressure so sealing heads cycle consistently.
Provides clean, adjustable air to a laboratory test bench or pilot-plant rig where instruments and small actuators need a precise, repeatable set point read locally in psi on the embedded square gauge.
Start with the port step: this size 200 unit carries a 1/8 in port, so step up to GFR300/400/600 if the line's flow demand calls for a larger port. Choose the drain to match the installation: manual drain (this unit) means an operator bleeds the bowl, an automatic drain (code A) discharges condensate on its own, and the differential-pressure default drains on pressure differential. The 40 um element is the standard grade; specify 5 um (code W) where finer particulate removal is needed. The embedded square gauge on this unit reads psi; MPa and bar scales are also available, and an external round gauge is optional. Thread is NPT here; PT is the standard and G (BSPP) is the other orderable option. A bracket is included on this unit. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application's flow and pressure requirements and we will confirm the datasheet curve figures for this 1/8 in, size 200 unit on request before you order.
The M in the code means the bowl is drained by hand: an operator opens the drain to bleed off collected condensate. That suits installations that are checked regularly. If the unit sits where nobody drains it, order the automatic-drain variant (code A), or the differential-pressure default, so water is discharged without manual attention.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.