The AirTAC GFR200C06MJC2TK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MJC2TK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built around a 1/8 in NPT port, a manual drain bowl, a 40 um standard filter element, a round pressure gauge with a psi scale, and a built-in reverse (check) valve; it is supplied without a mounting bracket. Maximum working (inlet) pressure is 1.0 MPa (145 psi), the operating temperature range is -5 to 70 C (non-freezing), and the regulation range for this manual-drain version is 0.05-0.9 MPa (7-130 psi).
This is a genuine AirTAC part in the 200 size of a series that runs from 200 to 600, where larger sizes carry larger ports and more flow. Options across the GFR range include automatic or differential-pressure drains, a 5 um filter element (code W), an embedded square gauge or an external round gauge with MPa, psi or bar scales, and G or NPT threads in place of the PT standard. Flow is published as curves rather than a single rating, so ask us to confirm the figures for your application.
| Model | GFR200C06MJC2TK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
A point-of-use filter regulator on the air drop feeding a punch press control circuit: the 40 um element strips water and swarf from the shop line, the regulator holds the set pressure to the valve stack, and the manual drain is blown down at end of shift.
Supplying clean, regulated air to the gripper and cylinder circuit of an electronics pick-and-place cell, with the round psi gauge giving operators a direct readout at the cell and the built-in check valve fitted in the air path.
Conditioning the supply on a laboratory pneumatic test bench: particulate and moisture are filtered out ahead of sensitive instruments, and the regulator lets a technician dial in a stable set pressure read in psi.
The real choices in this family are the size and port step, the drain type, the filter grade and the gauge. This unit is size 200 with a 1/8 in NPT port; step up to 300, 400 or 600 when the application's flow demand outgrows the port. The manual drain fitted here gives the widest regulation span, 0.05-0.9 MPa (7-130 psi), while automatic and differential-pressure drain versions adjust over 0.15-0.9 MPa (20-130 psi). The 40 um element is standard and a finer 5 um element is available as code W. The round gauge here reads in psi; square embedded gauges and MPa or bar scales are alternatives. Flow is published as curves, not a single rating, so send us your application and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so there is no one number we can honestly quote. Tell us your application and operating pressure and we will confirm the flow figures from the datasheet on request before you order.
A manual drain means someone opens the bowl drain by hand to expel collected water, which suits duties with regular operator attention. Automatic (code A) and differential-pressure (the series default) drains remove condensate without that step, but their regulator adjustment range is 0.15-0.9 MPa (20-130 psi); the manual-drain version spans 0.05-0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.