The AirTAC GFR200C06MJC2WGK AirTAC Filter Regulator G1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MJC2WGK is a GFR-series filter regulator: water and particulate removal plus pressure regulation combined in a single body, with no lubricator. This size 200 unit is ported G1/8 (G thread), carries the fine 5 um filter element (code W), drains by hand via the manual drain, and is fitted with an external round gauge reading in psi. A reverse/check valve (code K) is built in and the unit is supplied without a mounting bracket (code J). Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the GFR range, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um fine filtration, square or round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200C06MJC2WGK AirTAC Filter Regulator G1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Compact cylinders and grippers on a carton-forming station get clean, dry air at a set pressure from one G1/8 unit, with the 5 um element protecting small pilot valves from particulate carryover.
Clamp and unclamp actuators need a steady, regulated supply; the built-in check valve holds the circuit against momentary upstream pressure loss while the regulator keeps clamp force consistent.
Directional control valves driving filler and capper actuators draw from a filtered, regulated branch; the manual drain lets an operator clear accumulated condensate during scheduled changeovers.
Start with the size and port: 200 is the smallest G-series frame, and stepping up through 300, 400 and 600 buys larger ports and more flow, so match the frame to the air demand of the circuit rather than to the pipe alone. This unit already fixes several choices for you: 5 um filtration instead of the 40 um standard element, a manual drain instead of the differential-pressure default, a round psi gauge, a reverse/check valve, and no bracket. If you would rather drain automatically or by differential pressure, or need a square gauge in MPa or bar, those exist as other codes in the same family. Thread is G here; PT is the standard and NPT is also an order option. Because flow is published as curves and not as a single rated number, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a l/min or SCFM number. Tell us your operating pressure and air demand and we will confirm the sizing from the datasheet on request before you order.
The M in the code selects the manual drain: an operator opens it by hand to expel collected condensate, which suits duties with regular maintenance visits. The family also offers a differential-pressure drain (the default) and an automatic drain (code A) as separate codes, so you can switch drain type by choosing the matching model.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.