The AirTAC GFR200C06MJC2WK AirTAC Filter Regulator PT1/8 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MJC2WK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure (0.05-0.9 MPa / 7-130 psi adjustment range on this manual-drain version) in a single body. This configuration is sized GFR200 with a PT 1/8 in port, a metal bowl with manual drain, a 5 um filter element (the finer of the two catalogue grades), a round pressure gauge reading in psi, and a reverse/check valve that helps hold downstream pressure when supply dips. No mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, plus drain, filter-grade, gauge-scale, thread and bracket options, so a matching unit can be specified as requirements change. Maximum inlet pressure is 1.0 MPa (145 psi) and working temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating; ask us to confirm flow and other datasheet figures for your application.
| Model | GFR200C06MJC2WK AirTAC Filter Regulator PT1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding clean, regulated air to the tool-change and clamping circuits on a machining centre, with the 5 um element protecting fine valves and the check valve helping hold set pressure during supply dips.
Regulating air to carton-forming and sealing cylinders on a packaging conveyor, where the manual drain lets an operator bleed accumulated water from the bowl at the start of a shift.
Mounted at the inlet of a control panel to give one filtered, regulated supply to solenoid valves and I/P devices, with the round psi gauge providing a local setpoint readout.
The real choices in this family are the size and port step (200 through 600, 1/8 in to 1 in), set against the air your circuit needs; the drain type (differential-pressure as standard, automatic, or manual as fitted here); the filter grade (40 um standard, 5 um as fitted here for finer protection of downstream devices); the gauge and its scale (MPa, psi or bar); and the thread (PT is the standard, with G and NPT as catalogue order options). A mounting bracket is optional. Note that the regulation range differs by drain type, and that flow is published as curves rather than a single rated figure - ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so no single number is quoted here. Ask us to confirm flow from the datasheet against your application before ordering.
This configuration has a manual drain: an operator opens it to discharge water collected in the metal bowl. The same GFR200 body is available with automatic or differential-pressure drains as catalogue options - tell us if you would prefer one of those.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.