The AirTAC GFR200C06MJF2GK AirTAC Filter Regulator G1/8 Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MJF2GK is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation in a single size-200 body. This configuration carries a G1/8 (BSPP) port, a 40 um standard filter element, a manual drain on the bowl, an embedded square pressure gauge reading in psi, and a built-in reverse/check valve that holds the regulated circuit when upstream supply is lost. It ships without a mounting bracket (code J). Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator adjustment range with manual drain is 0.05-0.9 MPa (7-130 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options include automatic or differential-pressure drains, a 5 um element (code W), G or NPT threads, gauge scale choices, and bracket variants. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GFR200C06MJF2GK AirTAC Filter Regulator G1/8 Manual Drain |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Cleaning and regulating the air feeding a machining centre's tool-clamp and coolant-door cylinders at the machine drop, where the 1/8 in port matches compact point-of-use piping and the check valve holds clamp position during supply dips.
Conditioning air for the sealing arms and pusher cylinders on a beverage carton line, with the psi gauge letting line staff set and verify sealing pressure at a glance and the manual drain cleared during scheduled changeovers.
Supplying filtered, regulated air to gripper actuators in a small robot cell, where the compact size-200 footprint fits inside the cell cabinet and the 40 um element protects the gripper valve manifold.
Size 200 with a G1/8 port is the entry step of the GFR range; step up through 300, 400 and 600 when your line needs larger ports and more flow. Drain choice matters in practice: this unit has a manual drain (code M), which suits stations attended on a maintenance schedule, while automatic (A) and differential-pressure (blank) drains suit unattended duty. The 40 um element fitted here is the standard grade; specify code W for the 5 um element where finer particulate removal is needed. The square gauge reads in psi; MPa and bar scales are also available, and an external round gauge is an option. Thread is G (BSPP) on this unit; PT is the standard catalogue thread and G/NPT are order options. A bracket can be added where panel or wall fixing is required. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your application and operating pressure and we will confirm the flow data from the datasheet on request before you order.
The M in the code means the bowl drain is operated by hand, which suits stations checked on a maintenance schedule. For unattended duty you can order the same regulator with an automatic drain (code A) or the differential-pressure drain (blank), which are the other catalogue options for this family.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.