The AirTAC GFR200C06MJF2WGK AirTAC Filter Regulator G1/8 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MJF2WGK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built around a G1/8 (1/8 in) port with G thread, the finer 5 um filter element (code W, against the 40 um standard), a manual drain on the metal bowl, an embedded square gauge scaled in psi, and a fitted reverse (check) valve that holds downstream pressure if the supply dips. No mounting bracket is fitted (code J).
It is a genuine AirTAC part in the 200 size of a family that spans 200, 300, 400 and 600 with ports from 1/8 in to 1 in. Maximum inlet pressure is 1.0 MPa (145 psi), the regulation range for this manual-drain version is 0.05-0.9 MPa (7-130 psi), and the working temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing and the full datasheet for your application.
| Model | GFR200C06MJF2WGK AirTAC Filter Regulator G1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, regulated air to solenoid valves and pneumatic clamps on a CNC machining cell. The 5 um element guards fine valve spools, the psi gauge lets setters verify clamp pressure, and the check valve holds the clamps if shop air dips.
Regulated air for actuated valves on a chemical dosing or laboratory automation skid. The metal bowl suits surroundings where a polycarbonate bowl is not wanted, and the manual drain fits a supervised maintenance routine.
Regulated supply to diverter and stopper cylinders on a parcel-sortation conveyor. The square psi gauge makes setpoint checks quick at shift changeover, and the manual drain supports a fixed daily bleed routine.
Choose the size by port and demand: the 200 sits at the small end of the GFR range (1/8 in to 1 in ports across 200/300/400/600), so step up a size if your line draws more air. Drain type is a real choice: this unit is manual (bleed the bowl at inspection), while automatic and differential-pressure drains suit installations without scheduled checks. The 5 um W element in this code is the finer option over the 40 um standard - pick it to protect sensitive valves. The embedded square gauge is standard with a selectable scale (MPa, psi or bar; this unit is psi), and an external round gauge is optional. Thread: PT is the standard, with G (BSPP) and NPT as order options - this unit is ordered in G. Brackets are optional on GFR; this configuration has none. Flow is published as curves, not a single rating, so send us your demand figures and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application demand (port size, working pressure and air consumption) and we will confirm sizing from the datasheet on request.
The W code fits the finer 5 um element, which strips smaller particulate before it reaches sensitive valves and cylinders; the 40 um grade is the standard choice for general supply. Both are catalogue options on GFR filter regulators, and the manual drain in this code means the metal bowl is bled at inspection.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.