The AirTAC GFR200C06MJF2WK AirTAC Filter Regulator 1/8 in PT, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MJF2WK is a size-200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is built around a 1/8 in PT port, a 5 um filter element (the fine W grade, one step finer than the 40 um standard), a manual drain bowl, and a standard regulator with an adjustment range of 0.05-0.9 MPa (7-130 psi). An embedded square gauge reading in psi is fitted, a reverse/check valve is included to hold downstream pressure, and no mounting bracket is supplied. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, square or external round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads as order options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GFR200C06MJF2WK AirTAC Filter Regulator 1/8 in PT, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use conditioning ahead of a CNC machine tool's pneumatic valves and tool-change cylinder circuit: the 5 um element polishes the air and the regulator holds a steady set pressure for consistent clamping and actuation.
Mounted at the drop feeding a packaging conveyor's pneumatic stoppers, diverters and pushers, giving the line a single filtered-and-regulated supply with a local psi gauge the operator can check at a glance.
Installed upstream of a small robotic pick-and-place manifold driving grippers and vacuum ejectors, where the check valve helps hold the set downstream pressure and the 5 um grade protects fine pilot components.
Size the GFR200 by port and expected flow: size 200 with a 1/8 in PT port is the smallest step in the GFR range, and larger sizes (300/400/600) step up in port and flow capacity - published as curves, not a single rating, so confirm sizing against your application before ordering. This unit carries the 5 um element (code W); choose 40 um for general-purpose air and 5 um where finer particulate removal matters. The manual drain suits installations where an operator can bleed the bowl periodically; automatic or differential-pressure drains are available if the unit will be left unattended. The fitted square gauge reads in psi; MPa or bar scales and an external round gauge are options. PT is the standard thread, with G (BSPP) and NPT available to order. No mounting bracket is included with this code (J); brackets are optional on other configurations.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as performance curves rather than a single rated figure, so we do not quote one number here. Tell us your inlet pressure, set pressure and expected air demand and we will confirm the flow figures from the datasheet for this exact model before you order.
The M in the code means the bowl is drained by hand: an operator opens the drain periodically to release collected water. It suits stations that are visited daily. If the unit will be left unattended, choose the automatic (A) or differential-pressure (blank) drain version instead - both are available in the same size, and the manual-drain version carries the wider 0.05-0.9 MPa (7-130 psi) adjustment range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.