The AirTAC GFR200C06MJNTK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MJNTK is a size-200 filter regulator: it removes water and particulate from compressed air and holds downstream pressure at your setpoint in one compact body. This configuration has a 1/8 in NPT port, a 40 um standard filter element, a manual drain bowl in polycarbonate, a standard regulator with a 0.05-0.9 MPa (7-130 psi) adjustment range, and a built-in reverse (check) valve so downstream pressure is held if the supply drops. No pressure gauge is fitted on this version and no mounting bracket is included; both are available as ordering options.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of manual, automatic or differential-pressure drains, a 5 um optional element, gauge and thread variants, and a low-pressure type. Maximum working pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm sizing or any datasheet figure for your application before ordering.
| Model | GFR200C06MJNTK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding the pneumatic taping and flap-folding cylinders on a carton-sealing line: the 40 um element strips water and pipe scale before they reach the valves, while the regulator holds a steady setpoint so case clamping stays consistent through the shift. The manual drain suits a machine tended by an operator each shift.
Air preparation for fixture clamps and swing cylinders on a machining cell: filtered, regulated air keeps clamping force repeatable part after part, and the fitted check valve holds clamp pressure if the shop air supply dips mid-cycle. The 1/8 in port suits the compact point-of-use drop.
Supplying the divertor and stopper gates on a parcel-sorting conveyor: the filter keeps moisture and debris out of the gate cylinders and solenoid valves, and the regulator pins the pressure so gate timing does not drift as the main line pressure wanders.
Start with the port step: this unit is the 200 size with a 1/8 in NPT port, so match it to the line size and the air demand of the equipment downstream - larger GFR sizes (300/400/600) carry bigger ports for higher demand. Choose the drain to suit access: manual (as here) means an operator drains the bowl, automatic drains condensate on its own, and the differential-pressure default drains on pressure drop. The 40 um element is standard; specify the W variant if the application needs 5 um filtration. Gauges (embedded square or external round, with MPa, psi or bar scales) and a mounting bracket are options, and PT is the standard thread with G (BSPP) and NPT as order variants - this code is the NPT version. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a l/min, m3/h or SCFM number. Send us your application - line pressure, setpoint and the equipment downstream - and we will confirm the sizing from the datasheet before you order.
The M in the code specifies a manual drain: condensate collects in the polycarbonate bowl and an operator opens the drain at intervals. Choose the automatic-drain variant if the unit sits in an inaccessible spot or the line runs unattended; the differential-pressure drain (the default code) is the third option. All three share the same 0.05-0.9 MPa (7-130 psi) regulation range on this family.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.