The AirTAC GFR200C06MLC1WTK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MLC1WTK is a filter regulator: a water-and-particulate filter and a pressure regulator combined in one compact body, so a single component cleans the compressed air and holds your set pressure downstream. This 200-size unit is built with a 1/8 in NPT port, a 5 um filter element, a manual drain, a low-pressure regulator, a round pressure gauge scaled in MPa, a reverse/check valve and a mounting bracket, and it carries a metal bowl. It works on compressed air at up to 1.0 MPa (145 psi) inlet and -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, and options across drain type, 40 um or 5 um filtration, gauge style and scale (MPa, psi or bar), PT, G or NPT threads, and check valves. Because flow for this family is published as curves rather than a single rating, we confirm the datasheet and flow figures for your application on request.
| Model | GFR200C06MLC1WTK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a small assembly cell, this unit filters water and swarf out of the shop air line and holds a low, stable regulated pressure to the clamping cylinder, with the check valve holding the set pressure if the upstream supply dips.
Feeding the air cylinders and grippers of a carton-sealing or labelling station, the 5 um element protects fine sealing components from particulate while the low-pressure regulator keeps actuation pressure gentle on lightweight packaging.
On automated sampling or analytical equipment, the unit conditions instrument air to a controlled low pressure with fine 5 um filtration, and the manual drain lets technicians remove accumulated condensate during scheduled maintenance.
Pick the size and port against the air your circuit actually consumes: 200 is the compact step with a 1/8 in NPT port on this unit, while 300, 400 and 600 carry larger ports and more flow. This configuration already fixes several choices: the 5 um W-grade element (finer than the 40 um standard), a manual drain you operate by hand, a low-pressure regulator, and a round gauge scaled in MPa. If you would rather have a differential-pressure or automatic drain, the 40 um standard grade, a square embedded gauge, a psi or bar scale, a PT or G/BSPP thread, or no bracket, those are orderable options within the same family. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
Flow for the GFR200 series is published as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and datasheet figures for this exact model on request.
The L code marks the low-pressure regulator variant, intended for circuits where the working pressure sits below what a standard regulator setting targets. The exact adjustment range for this variant is not published in the material we hold, so we confirm it on request. Maximum inlet pressure remains 1.0 MPa (145 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.