The AirTAC GFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$41.72 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure

The AirTAC GFR200C06MLC2 is a size 200 filter regulator that removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration carries a PT1/8 port, a 40 um standard filter element, a manual drain bowl in polycarbonate, and a low-pressure regulator type, with a round pressure gauge reading in psi fitted. A mounting bracket is included, and the unit works at up to 1.0 MPa (145 psi) inlet pressure in a -5 to 70 C (non-freezing) environment.

This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, a choice of manual, automatic or differential-pressure drains, 40 um or 5 um (code W) filtration, gauge style and scale options, and G or NPT thread variants to order. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure Technical Specifications

ModelGFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure Is Used

tune

Low-pressure glue and coating lines

Packaging and converting machines often run glue heads, coating bars or air knives at reduced pressure. This filter regulator cleans the supply and holds the low setpoint the process needs, with the psi gauge giving the operator a direct readout.

precision_manufacturing

Clamping circuits on machining fixtures

Pneumatic clamps and swing cylinders on a fixture plate need filtered air held at a gentle, stable pressure to avoid damaging the workpiece. The low-pressure type regulator in this unit is aimed at exactly that kind of circuit at a PT1/8 take-off point.

science

Laboratory and test bench air supply

Bench rigs and lab apparatus fed from a shop-air drop need water and particulate removed and the pressure trimmed down to a low, repeatable setting. This unit does both in one body, and the manual drain suits a bench that is bled down between runs.

Is the GFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure the Right Unit?

Start with the port step: size 200 with a PT1/8 port suits compact circuits, and larger sizes (300/400/600) move up in port and flow capacity - match the size to the air demand of the circuit. Choose the drain to suit access: this unit has a manual drain, so someone must bleed the bowl periodically; automatic or differential-pressure drains suit unattended installations. Filtration is 40 um standard, with 5 um (code W) where downstream equipment needs finer protection. Gauge scale (MPa, psi or bar) and thread (PT standard, G or NPT to order) are decodable choices, and a bracket is included here.

One honest note before ordering: flow is published as curves, not a single rated figure, so send us your application details and we will confirm sizing against the datasheet before you commit.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your application and we will confirm the flow behaviour from the datasheet for this exact PT1/8, size 200 configuration before you order.

The M in the code sets a manual drain: condensate collects in the polycarbonate bowl and is released by opening the drain when needed. It is the right choice where the unit is visible and checked routinely. If the installation is inaccessible or unattended, ask about the same model with an automatic or differential-pressure drain instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C06MLC2 AirTAC Filter Regulator PT1/8 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C06MLC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.