The AirTAC GFR200C06MLC2W AirTAC Filter Regulator, PT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MLC2W is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 200-size unit is fitted with a PT1/8 (1/8 in) port, a 5 um filter element for finer filtration than the standard 40 um grade, a manual drain for the metal bowl, and a round pressure gauge reading in psi. It is a low-pressure type regulator, and a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with choices of thread (PT standard, G and NPT as order options), drain type, filter grade, gauge style and scale. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GFR200C06MLC2W AirTAC Filter Regulator, PT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a carton-sealing or case-packing machine, delicate clamp and hold-down cylinders often need a lower, closely controlled supply than the main header. This filter regulator cleans the air of water and fine particles and lets a technician set the clamping pressure locally, with the psi gauge giving a direct readout at the machine.
Mist-free chip-blowing nozzles and air-wipe jets around a CNC machining centre work best at reduced pressure. Feeding them from this PT1/8 filter regulator keeps swarf and moisture out of the small orifices while the low-pressure type regulator holds a gentle, stable setting independent of the shop header.
Bench-top test rigs and lab automation that use air bearings, purge flows or pneumatic actuators need air that is both dry and finely filtered. The 5 um element protects sensitive components, the manual drain suits periodic maintenance schedules, and the low-pressure regulation keeps instrument supply pressures well below line pressure.
Choose the size and port step against the air consumption of the circuit: this unit is size 200 with a PT1/8 port, the smallest step in the GFR range, so step up to GFR300/400/600 if the line needs more capacity. The 5 um element (code W) suits circuits that need finer filtration than the 40 um standard; keep the standard grade where only coarse water and particle removal is needed. The manual drain means someone bleeds the bowl periodically - pick the automatic or differential-pressure drain option where the unit cannot be serviced regularly. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are the other catalogue choices. Thread is PT as standard, with G (BSPP) and NPT available to order, and a mounting bracket is included with this model.
Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number. Tell us your application and air consumption and we will confirm the flow curve and sizing from the datasheet on request.
The M in the code specifies a manual drain: condensate collected in the bowl is released by hand at service intervals, which suits installations that are checked regularly. If the unit will be mounted where it cannot be serviced often, the same GFR200 body is available with an automatic or a differential-pressure drain - ask us for that variant code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.