verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8

The AirTAC GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$53.46 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8

The GFR200C06MLC2WTK is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This size-200 configuration is built around a 1/8 in NPT port, carries a 5 um filter element for finer cleaning than the standard 40 um grade, and drains collected condensate by hand through its manual drain. The regulator is the low-pressure type, and the fitted round gauge reads in psi so you can see and set downstream pressure directly. A reverse (check) valve is fitted, the unit includes a mounting bracket, and the bowl is metal. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600, with port sizes from 1/8 in up to 1 in, a choice of manual, automatic or differential-pressure drains, 40 um or 5 um filtration, gauge styles and MPa/psi/bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and any datasheet figure against your application before ordering.

GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8 Technical Specifications

ModelGFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8 Is Used

build

Low-pressure clamping on a machining fixture

Pneumatic clamps on a fixture plate often need a lower holding pressure than the main shop air line delivers. This unit filters the supply to 5 um, regulates it down with the low-pressure type regulator, and shows the set pressure on the round psi gauge at the clamp manifold.

air

Air knife and blow-off on a bottling line

Blow-off nozzles that dry bottles or labels before filling run best at reduced, stable pressure. Mounted at the take-off point with its 1/8 in NPT port, this unit cleans the air to 5 um, holds the low blow-off pressure, and its check valve backs up the downstream circuit.

science

Regulated air supply on a laboratory test bench

Test rigs and pilot rigs need clean air at a repeatable low setting. The 5 um element protects sensitive instrumentation, the low-pressure regulator trims the supply down gently, the psi gauge documents the set point, and the bracket gives tidy panel mounting.

Is the GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8 the Right Unit?

Choose the size and port step against the air your circuit actually uses: this unit is size 200 with a 1/8 in NPT port, the smallest step in the GFR range, so step up to 300/400/600 if your line needs more capacity. If 5 um protection is finer than you need, the standard 40 um grade in the same family is the economical choice; keep 5 um where downstream valves, cylinders or instruments are sensitive. Drain choice matters: manual drain (this unit) suits accessible mounting and light condensate loads, while automatic or differential-pressure drains suit unattended duty. Gauge scale is selectable (MPa, psi or bar) and this configuration carries a round psi gauge. Thread is NPT here; PT is the standard thread and G is also a catalogue option to order. A bracket is included; a no-bracket variant exists in the family.

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated number, so we cannot quote a rated flow figure. Send us your application details and we will confirm the right size from the datasheet before you order. The exact adjustment range of the low-pressure regulator type is likewise confirmed from the datasheet on request.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8 FAQ

AirTAC publishes flow for the GFR family as performance curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Tell us your application and line pressure and we will confirm the correct size and the flow figures from the datasheet on request before you order.

The manual drain (code M) means condensate collected in the metal bowl is released by hand, which suits accessible mounting points with light to moderate water carry-over. The same GFR family is also available with an automatic drain (code A) or the differential-pressure drain that is the family default, so choose those where the unit cannot be attended regularly. Note that the regulator adjustment range differs by drain type in this family, and for this low-pressure type we confirm the exact range from the datasheet on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C06MLC2WTK AirTAC Filter Regulator NPT1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C06MLC2WTK and will confirm price, stock and lead time — usually within 7-8 hours.