The AirTAC GFR200C06MLC3WT AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MLC3WT is a GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This 200-size unit is fitted with 1/8 in NPT ports, a 5 um filter element (code W) for finer filtration than the standard 40 um grade, and a manual drain on the metal bowl so condensate is released only when an operator opens it. It is the low-pressure regulator type, and a round pressure gauge with a bar scale is included; a mounting bracket is supplied for panel or surface fixing.
This is a genuine AirTAC part. The GFR family is published in 200, 300, 400 and 600 sizes with a choice of PT, G and NPT threads, 40 um or 5 um filtration, differential-pressure, automatic or manual drains, standard or low-pressure regulation, and gauge options. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GFR200C06MLC3WT AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding filtered, low-pressure regulated air to analytical instruments and sample-handling pneumatics in a lab, where the 5 um element protects sensitive fittings and the manual drain suits supervised equipment.
Conditioning the atomizing air supply at a paint or coating booth, where fine filtration keeps the finish clean and the low-pressure regulator type matches gentle atomizing pressures.
Supplying filtered, regulated air to low-pressure pneumatic valves and small actuators on a bottling or filling line, with the round bar gauge giving operators a local pressure reference.
Size and port set the capacity envelope: this unit is size 200 with 1/8 in NPT ports, the smallest GFR step, so step up to 300, 400 or 600 if your line needs larger ports and more flow. The 5 um element (code W) suits air that feeds sensitive components; choose the standard 40 um grade where only bulk water and coarse dirt matter. The manual drain here means an operator drains the bowl; pick automatic or differential-pressure drain where unattended condensate removal is preferred. A round gauge with a bar scale is fitted on this code; square embedded gauges and MPa/psi/bar scales are the other catalogue options.
Thread is NPT on this code; PT is the standard and G (BSPP) is also an order option, so match the thread to your piping before ordering. A mounting bracket is included. Because flow for this series is published as curves and not as a single rated figure, and this is the low-pressure regulator type whose exact adjust range is not published, ask us to confirm both against your application before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so no rated flow figure can be quoted for this unit. Tell us your line pressure, downstream demand and port size, and we will confirm the flow and sizing from the datasheet on request before you order.
The M in the code selects the manual drain: condensate collected in the metal bowl is released only when someone opens the drain. That suits supervised stations and low-condensate duty. If the unit will run unattended where water collects, ask about the automatic or differential-pressure drain variants of the same GFR200 size.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.