The AirTAC GFR200C06MLF2T AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MLF2T is a GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This configuration is the size-200 unit with 1/8 in NPT ports, a manual drain bowl, the standard 40 um filter element, the low-pressure regulator type, and an embedded square gauge reading in psi. A mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and options including automatic or differential-pressure drains, a 5 um element (code W), alternative gauge scales, and G or NPT threads in place of the PT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm figures against your application.
| Model | GFR200C06MLF2T AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtering and regulating the air feeding clamping cylinders on a CNC fixture, where the operator purges the manual drain bowl at shift start and reads the square psi gauge when setting clamp pressure.
Conditioning air and stepping pressure down for pilot and signal lines on a carton-sealing line, with the low-pressure type suiting circuits that run well below full line pressure.
Supplying cleaned, regulated air to a laboratory test bench where the technician sets pressure on the embedded psi gauge and drains collected water manually between runs.
Sizes step through 200/300/400/600 with port sizes from 1/8 in up to 1 in, so pick the size whose published flow curve covers your air demand at working pressure - we can check that with you before you order. The real decode choices in this family are: drain type (manual as fitted here, versus automatic or differential-pressure), filter grade (40 um standard, 5 um with code W), gauge scale (MPa, psi or bar), and thread (PT is the standard; G and NPT are order options). This unit is the low-pressure type; the exact low-pressure adjustment range is not published, so confirm your regulated-pressure window with us first. A bracket is included.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not quote a number. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request.
The M in the code specifies a manual drain bowl, which an operator opens to purge collected water. Automatic (code A) and differential-pressure (blank) drains are available in the same family if you would rather not rely on manual purging.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.