The AirTAC GFR200C06MLF2WG AirTAC Filter Regulator G1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MLF2WG is a size-200 filter regulator: water and particulate filtration plus pressure regulation combined in a single body, with a G1/8 (BSPP) port. This configuration is the low-pressure regulator type, so it suits circuits that hold a reduced pressure below the range of a standard unit. It carries a 5 um filter element (the finer of the two published grades), a manual drain bowl in metal, an embedded square gauge reading in psi, and a mounting bracket. No reverse/check valve is fitted.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch and options for drain type, filter grade, gauge style and scale, thread (PT standard, G and NPT orderable) and bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing or any datasheet figure against your application before ordering.
| Model | GFR200C06MLF2WG AirTAC Filter Regulator G1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds and regulates the air to light-duty clamping cylinders that must hold a reduced, stable pressure rather than full line pressure, with the 5 um element protecting the cylinder seals from fine particulate.
Serves as the point-of-use filter regulator ahead of sensitive analysers or test rigs that need clean, low-pressure air, with the psi square gauge giving a direct local reading at the bench.
Filters and steps the supply air down for spray guns and air-assisted applicators on a finishing line, where fine 5 um filtration helps keep the atomizing air free of water and particle carryover.
Start with the port step: size 200 with a G1/8 port is the smallest GFR frame, so match it to the line size and the flow your circuit needs - we can check the published flow curves against your demand on request. Choose the low-pressure regulator type (this code) when your set pressure sits below what a standard unit covers; the exact adjustment range for the low-pressure type is not published, so confirm it with us. This unit has a manual drain, which means someone drains the bowl on a routine - pick automatic or differential-pressure drain codes if unattended drainage matters. The 5 um element (code W) is the finer grade versus the 40 um standard; keep 5 um where downstream equipment is sensitive to finer particles. Gauge scale is psi here; MPa and bar scales are available. Thread is G (BSPP); PT is the standard thread and NPT is an orderable option. A bracket is included.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line size and demand and we will confirm the flow from the datasheet curves against your application before you order.
The M in the code selects a manual drain: the bowl is drained by hand on a routine, unlike the automatic or differential-pressure drain options in the series. The W selects the 5 um filter element, the finer grade versus the 40 um standard, for downstream equipment that needs cleaner air.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.