The AirTAC GFR200C06MLF3T AirTAC Filter Regulator 1/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MLF3T is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in one body. This unit is built for a 1/8 in NPT port, is the low-pressure regulator type, and drains its polycarbonate bowl by hand via the manual drain. Filtration is the standard 40 um element, an embedded square gauge with bar scale is fitted, a mounting bracket is included, and no reverse/check valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 5 um element option (code W), gauge scales in MPa, psi or bar, and PT, G or NPT threads. AirTAC publishes flow for this series as curves rather than a single rated figure, so ask us to confirm flow and datasheet figures for your application before ordering.
| Model | GFR200C06MLF3T AirTAC Filter Regulator 1/8 in NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding pneumatic clamps and hold-downs on a cartoning or wrapping line, where the circuit needs a setpoint below the standard regulator range and clean, moisture-reduced air at the point of use.
Point-of-use conditioning for the cylinder-driven stops, diverters and pushers along a bottling conveyor, with the square bar gauge giving operators a local pressure readout at the machine.
Conditioning compressed air for lab rigs and test benches that run at reduced pressure, where the manual drain suits an attended bench and the 1/8 in port matches small tubing runs.
Size and port are the first choice: step up from 200 to 300, 400 or 600 for larger ports and more flow, matching the 1/8 in NPT connection here to your supply line. Drain type matters in service: the manual drain on this unit is emptied by hand and suits positions someone visits regularly, while automatic (code A) and differential-pressure (no code) drains suit less attended installations. The 40 um element is standard; specify the W option for 5 um where finer particulate removal is needed. Gauge scale (MPa, psi or bar - bar on this unit) and thread (PT standard, G or NPT to order) are decodable options, and the bracket can be omitted with the J code. Because AirTAC publishes flow as curves rather than a single rating, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as performance curves rather than a single rated figure, so there is no one flow number we can quote for the 1/8 in port. Send us your required flow and working pressure and we will confirm the sizing from the datasheet on request.
The M in the code specifies a manual drain: the bowl is emptied by hand, which suits positions that are checked regularly. The same GFR200 size can be ordered with an automatic drain (code A) or the differential-pressure drain (no code) for less attended installations.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.