The AirTAC GFR200C06MLJC1WTK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MLJC1WTK is an AirTAC GFR200 filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This configuration is built with 1/8 in NPT ports, a 5 um filter element (code W) for finer air cleaning than the standard 40 um grade, a manual drain that is emptied by hand, and the low-pressure regulator type for circuits set below standard pressures. A round pressure gauge scaled in MPa is fitted, a reverse/check valve is included, and no mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in and thread options PT (standard), G (BSPP) and NPT, with drain, filter grade, gauge and bracket choices to match the unit to your line. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06MLJC1WTK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtering and regulating supply to the low-pressure clamping cylinders on a packaging machine's rotary table, with the 5 um element protecting the small control valves downstream.
Cleaning and stepping down compressed air at a bench drop on a test-laboratory air ring main, where the 5 um grade and the fitted MPa gauge give fine, readable control.
Feeding the divert cylinders on a parcel-sort conveyor line, with the reverse/check valve holding the circuit against backflow when upstream pressure drops.
Sizing starts with the port step: this unit is size 200 with 1/8 in NPT ports; step up through sizes 300, 400 and 600 when the line needs a larger port and more flow. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering. The 5 um element (code W) suits finer air cleaning; the standard grade is 40 um. The manual drain needs an operator to bleed collected condensate - choose the automatic (A) or differential-pressure (blank) drain codes if the unit will run unattended. The low-pressure regulator type covers lower set pressures; its exact range is not published, so confirm it with us. The gauge fitted here is the external round type scaled in MPa (psi and bar scales are order options), and the thread alternatives are PT (standard) and G (BSPP). Operating limits: max inlet 1.0 MPa (145 psi), -5 to 70 C, non-freezing.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure and expected air demand and we will confirm the datasheet figures for this exact model before you order.
Code M means the bowl is emptied by hand, which suits units an operator passes regularly. If this filter regulator will sit unattended, order the automatic (A) or differential-pressure (blank) drain code instead so collected water is removed without intervention.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.