The AirTAC GFR200C06MLJC2 AirTAC Filter Regulator PT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR200C06MLJC2 is an AirTAC GFR-series filter regulator: water-and-particulate filtration and pressure regulation combined in one body. This size 200 unit is threaded PT1/8 (1/8 in; G and NPT threads are order options), drains by hand through its manual drain, and carries the standard 40 um filter element (a 5 um element is available under code W). The regulator is the low-pressure type, and this configuration is fitted with an external round gauge reading in psi; no mounting bracket is included and no reverse/check valve is fitted. The polycarbonate bowl and unit are rated for a maximum inlet pressure of 1.0 MPa (145 psi) over a temperature range of -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and can be ordered with automatic, manual or differential-pressure drains, a 5 um element, embedded square or external round gauges in MPa, psi or bar scales, a reverse/check valve, and a mounting bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C06MLJC2 AirTAC Filter Regulator PT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a carton-sealing line, the GFR filters the shop air feeding the sealing cylinders and lets a technician set a gentle, low working pressure so the jaws close without crushing the carton, with the round psi gauge giving a direct local reading.
On a laboratory or QC test bench, the unit cleans the compressed air feeding instruments and fixtures and holds a low, stable set pressure while the technician watches the psi gauge at the bench.
Ahead of pneumatic valve positioners on a process skid, the filter regulator removes water and particulate from the pilot supply and regulates it down to the low pressure the positioner expects, with manual draining during scheduled rounds.
The real choices in this family are the size and port step, the drain type, the filter grade, the gauge and its scale, the thread, and the bracket. Step up from size 200 / PT1/8 when your line runs larger ports (1/4 to 1 in) and heavier air demand; the size number, not the port alone, sets the body and bowl scale. Choose the manual drain fitted here if someone can bleed the bowl as part of routine checks; automatic and differential-pressure drains suit unmanned or hard-to-reach installations. The 40 um element is standard; specify code W for 5 um where finer particulate protection matters. This unit is the low-pressure regulator type with a round psi gauge; embedded square gauges and MPa or bar scales are the other catalogue options. PT is the standard thread, with G and NPT available to order, and brackets are optional. Flow is published as curves, not a single rating, so send us your demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one number we can honestly quote. Tell us your line pressure and air demand and we will confirm the sizing from the datasheet on request.
The manual drain means the bowl is bled by hand as part of routine maintenance; automatic and differential-pressure drains are catalogue alternatives for unattended installations. This unit is also the low-pressure regulator type, whose set-pressure range is not published in the sheet we use, so we confirm it on request. The 40 um element is standard here; code W gives 5 um.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.