The AirTAC GFR200C06MLJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MLJC2T is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in one body. This size 200 configuration has a 1/8 in NPT port, a manual-drain metal bowl, a 40 um filter element and the low-pressure regulator type. It is fitted with the external round gauge reading in psi, and carries no mounting bracket (J code). Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, plus drain, filter-grade, gauge, thread and bracket options across the range. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C06MLJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a machining fixture with pneumatic clamps, this unit filters the shop air and holds a low regulated pressure suited to low-pressure type circuits, while the manual drain lets an operator clear accumulated water during shift checks.
Feeding the cylinders and ejectors of a carton-sealing station, the filter section removes water and particulate before they reach the valves, and the regulator holds a steady low set pressure for consistent box handling.
Supplying atomizing or blow-off nozzles in a coating or finishing line, the 40 um element keeps particles out of the nozzles and the low-pressure regulator holds the gentle, stable pressure the process needs, with the psi gauge giving a direct readout.
Within GFR you step through sizes 200, 300, 400 and 600 as your flow demand grows, with ports from 1/8 in up to 1 in. Drain is a real choice: this unit is manual (code M), meaning the bowl is drained by an operator at intervals; automatic and differential-pressure drains are available on other codes. Filter grade here is the 40 um standard; the 5 um option (code W) suits circuits sensitive to finer particles. Gauges: an embedded square gauge is standard and an external round gauge is optional, in MPa, psi or bar scales - this code carries the round psi gauge. Thread: PT is the standard, with G (BSPP) and NPT as order options; this code is NPT. The bracket is omitted on this code (J). Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number. Tell us your application and we will confirm the datasheet flow curves and check the sizing for you before you order.
The M in the code means the bowl is drained manually: an operator opens the drain at intervals to release collected water. It suits attended installations on a regular walk-round. If you want the bowl cleared without operator action, the automatic (A) and differential-pressure (blank) drain versions are available on other codes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.