The AirTAC GFR200C06MLJF1TK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MLJF1TK is an AirTAC GFR200 filter regulator: a single body that removes water and particulate from compressed air and regulates downstream pressure. This configuration has 1/8 in NPT ports, a metal bowl with manual drain, the standard 40 um filter element, and the low-pressure regulator type. It is fitted with an embedded square gauge scaled in MPa and a reverse (check) valve, and has no mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and the same filter-regulator function is offered with automatic or differential-pressure drains, a 5 um element (code W), square or round gauges scaled in MPa, psi or bar, PT or G threads, and an optional bracket. Flow for the series is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | GFR200C06MLJF1TK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a machining or assembly fixture, clamps are often set well below main line pressure. This unit filters the supply, holds a low regulated setting, and its built-in check valve keeps downstream pressure in the clamp circuit if the upstream supply dips.
Small pneumatic test rigs and analytical instruments frequently run on low-pressure air at compact 1/8 in connections. The 40 um element stops pipe scale and debris, and the manual drain lets an operator clear collected water from the metal bowl at the end of a run.
Rather than regulating one large header, individual workstations on an assembly line can each take a compact filter regulator at the drop. This size 200 unit suits a single station's low-pressure tools and actuators, with the square MPa gauge giving a local setpoint readout.
Choose the size and port against the air your circuit needs: this unit is size 200 with 1/8 in NPT ports, the smallest step in the GFR range, with larger sizes stepping up through 1/4, 3/8, 1/2, 3/4 and 1 in. Because AirTAC publishes flow as curves rather than a single rated number, ask us to check the curve against your application before ordering. The regulator here is the low-pressure type; AirTAC does not publish a separate numeric setting range for it in the material we hold, so we confirm the exact range from the datasheet on request. Other decodable choices: drain type (manual here; automatic and differential-pressure drains are offered), filter grade (40 um standard here, 5 um with code W), gauge (embedded square with MPa scale here; external round gauges and psi or bar scales are options), thread (NPT here; PT is the standard series thread and G is available), bracket (not fitted here; optional), and the reverse/check valve fitted here. If you also need lubrication, the GFC two-unit set pairs a filter regulator with a lubricator, and the GC three-unit set is the full F.R.L.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR-series flow as performance curves, not as a single rated figure, so we do not quote a number here. Tell us your application - inlet pressure, downstream demand and acceptable pressure drop - and we will confirm the flow curve and correct sizing from the datasheet before you order.
The M in this code means the metal bowl drains by hand: an operator opens the drain to expel collected water and dirt. It suits equipment that is attended at start-up or shutdown. If the installation runs unattended, the same GFR function is available with an automatic or a differential-pressure drain - we can quote those variants on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.