The AirTAC GFR200C06MLJF2TK AirTAC Low-Pressure Filter Regulator 1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MLJF2TK is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This unit is the 200 size with a 1/8 in NPT port, and it is the low-pressure type - ask us to confirm its adjustment range, which is not published in the standard tables. It carries a 40 um filter element, a manual-drain polycarbonate bowl, an embedded square gauge scaled in psi, and an integral reverse/check valve, and it is supplied without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans the 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, and each size can be ordered with a different drain type, 5 um filtration (code W), a different gauge scale, PT standard thread or G/NPT options, a bracket, and a reverse/check valve. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application before ordering.
| Model | GFR200C06MLJF2TK AirTAC Low-Pressure Filter Regulator 1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use conditioning ahead of directional valves on a packaging line: the 40 um element strips water and carryover particles while the low-pressure regulator holds a steady setting to the valve stack, with the psi gauge in plain view for repeat setups.
A filtered, regulated supply for laboratory rigs and test benches where instruments need clean air at a gentle, stable pressure; the square gauge scaled in psi makes settings easy to read, and the manual drain is emptied between sessions.
Conditioning the air feeding small conveyor stopper and pusher cylinders: the manual drain lets an operator bleed accumulated water at shift start, the 40 um element protects the cylinders, and the reverse/check valve is fitted as coded.
The real choices in this series are the size and port step (200 through 600, 1/8 to 1 in), set against the flow your line needs; the drain type (manual, automatic, or the differential-pressure default); the filter grade (40 um standard, 5 um with code W); the gauge and its scale (MPa, psi or bar); the thread (PT standard, G or NPT to order); the bracket; and whether a reverse/check valve is fitted. This code fixes those choices at 200 size, 1/8 in NPT, manual drain, 40 um, square psi gauge, check valve fitted, no bracket. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your inlet pressure and the flow your application needs, and we will confirm sizing against the datasheet on request.
The M in this code means a manual drain: an operator opens it to remove accumulated water from the bowl. The same family is also available with an automatic drain (code A) or the differential-pressure drain that is the default, and we can quote the variant that suits your maintenance routine.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.