The AirTAC GFR200C06MLJF2W AirTAC Filter Regulator PT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR family puts a water-and-particulate filter and a pressure regulator in one body: air is cleaned as it enters the bowl, then passes the regulating valve to the outlet. This GFR200C06MLJF2W is the compact 200 size with a 1/8 in PT port, a 5 um filter element (code W instead of the 40 um standard), a manual drain on the metal bowl, and the low-pressure regulator type (code L). A square pressure gauge scaled in psi is fitted as standard; no mounting bracket is supplied (code J) and no reverse/check valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi), with a working temperature range of -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR line spans sizes 200, 300, 400 and 600 with ports from 1/8 in up to 1 in, and options across the range include automatic or differential-pressure drains, the 40 um standard element, G (BSPP) or NPT threads, MPa/psi/bar gauge scales, an external round gauge and a mounting bracket. Flow for GFR units is published as curves rather than a single rating, so ask us to confirm the figures from the datasheet against your application before you order.
| Model | GFR200C06MLJF2W AirTAC Filter Regulator PT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding instruments, small test fixtures and pneumatic sensors on a bench circuit where the supply must be filtered to 5 um and held at a low, stable setting; the fitted square gauge reads the set point directly in psi.
Supplying paint guns and air brushes at a finishing station: the 5 um element strips water and particulate before the tip while the low-pressure regulator sets gun pressure, and the metal bowl is drained manually at the end of each shift.
Providing clean, reduced-pressure pilot air to process valves and small actuators on a loop that runs below standard plant pressure; the L-coded low-pressure regulator type is built for exactly that duty.
Size first: the 200 series is the compact frame, and the 06 code fixes a 1/8 in PT port, so match the port step against the air consumption of your circuit - flow is published as curves, not a single rating, so send us your line pressure and demand and we will confirm the fit from the datasheet before you order. This unit carries the W code (5 um element) instead of the 40 um standard, the M code (manual drain) instead of automatic or differential-pressure, and the L code (low-pressure regulator type; the exact adjustment range is not published, so ask us to confirm it for your set point).
The F2 code fits the embedded square gauge scaled in psi; MPa and bar scales, and an external round gauge, are the alternatives. The thread here is PT, which is the standard; G (BSPP) and NPT are catalogue options to order. No mounting bracket is included with the J code, and a reverse/check valve is not fitted on this variant.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and expected air consumption and we will confirm the sizing from the datasheet before you order.
The M code selects a manual drain: open the drain at the bottom of the metal bowl to expel collected water; there is no automatic or differential-pressure drain on this variant. The L code marks it as the low-pressure regulator type; its exact adjustment range is not published in the catalogue, so ask us to confirm it for your set point.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.