The AirTAC GFR200C06MLJF3WT AirTAC Filter Regulator NPT1/8 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MLJF3WT is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is the size 200 unit with a 1/8 in NPT port, a 5 um filter element (code W), a manual drain and a metal bowl. It is the low-pressure type; the exact regulation range for this variant is not published in the material we hold, so we confirm it on request. The embedded square gauge scaled in bar is fitted, no reverse/check valve is included, and the unit is supplied without a mounting bracket.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options including 40 um or 5 um filtration, differential-pressure, automatic or manual drains, MPa, psi or bar gauge scales, G (BSPP) or NPT threads in place of the PT standard, and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing and any datasheet figure for your application.
| Model | GFR200C06MLJF3WT AirTAC Filter Regulator NPT1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds the low-pressure clamping and sealing cylinders on a carton-sealing line: the 5 um element keeps moisture and debris out of the directional valves while the regulator holds a stable, reduced pressure to the actuators.
Supplies spray guns on a finishing line with air filtered to 5 um and regulated down to the low working pressure the gun needs; the manual drain lets an operator bleed accumulated water from the metal bowl at shift start.
Provides clean, low-pressure air to a bench-top test rig where the square gauge gives a direct bar-scale pressure readout and the low-pressure type matches circuits that never run at full line pressure.
Choose the size by port and flow: this unit is size 200 with a 1/8 in NPT port, the smallest step in the GFR range, so check it against your line's flow demand before ordering - AirTAC publishes flow as curves, not a single rating, and we will confirm the match from the datasheet on request. The 5 um element (code W) suits applications needing finer filtration than the 40 um standard, and the manual drain suits an accessible installation drained on a routine. The square gauge on this model reads in bar; MPa and psi scales and an external round gauge are alternatives. Thread is NPT here; PT is the AirTAC standard and G (BSPP) is also available to order. This configuration omits the mounting bracket and the reverse/check valve; both can be specified on other codes.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your required flow and working pressure and we will confirm against the datasheet curves whether this size 200 unit with the 1/8 in port is the right choice before you order.
The M specifies a manual drain: instead of an automatic or differential-pressure drain, an operator opens the drain at the bottom of the metal bowl to release collected water. It suits accessible installations drained on a routine. If you need unattended water removal, ask us about the automatic-drain and differential-pressure-drain variants of the same unit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.