The AirTAC GFR200C06MLNWT AirTAC Filter Regulator NPT 1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MLNWT is an AirTAC GFR-series filter regulator: a 5 um filter element and a pressure regulator combined in one body, so water and particulate are stripped from the compressed air and the downstream pressure is set from the same unit. This size 200 configuration has a 1/8 in NPT port, a manual drain for emptying the metal bowl, the low-pressure regulator type, and no gauge fitted; a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, and can be ordered with manual, automatic or differential-pressure drains, a 40 um standard or 5 um (W) element, embedded square or external round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Because flow for this series is published as curves rather than a single rating, we confirm the datasheet figures for your application on request.
| Model | GFR200C06MLNWT AirTAC Filter Regulator NPT 1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding paint or coating guns that run at reduced pressure: the 5 um element removes water and particulate that would blemish the finish, while the low-pressure regulator holds the gun supply steady.
Air preparation for fixture clamps and small swing cylinders that must actuate at a reduced, repeatable pressure; the combined filter-regulator saves panel space on the fixture manifold.
Supplying clean, low-pressure air to laboratory rigs, small actuators and pilot lines, where a compact 1/8 in unit with fine 5 um filtration protects sensitive downstream components.
The decodable choices are: size and port (200 here, 1/8 in NPT) stepped against the flow your line needs; drain type (this unit is manual drain - the bowl is emptied by hand, versus the automatic and differential-pressure options); filter grade (5 um here, the finer of the two grades, 40 um being standard); gauge (none fitted on this unit, so add a separate gauge if the set pressure must be read locally); and thread (PT is the standard, with G and NPT as order options - this unit is NPT). A mounting bracket is included.
Flow for this series is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so no rated flow number applies to this unit. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request.
This unit has a manual drain: the metal bowl must be emptied by hand periodically, whereas automatic and differential-pressure drain versions discharge condensate themselves. It is the low-pressure regulator type with a 5 um element and no gauge fitted; the exact set-pressure range for the low-pressure type is not published, and we confirm it from the datasheet on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.