The AirTAC GFR200C06MLNWTK AirTAC Filter Regulator 1/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MLNWTK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This unit is built on the size 200 frame with a 1/8 in NPT port and carries a 5 um filter element, the finer of the two catalogue grades. It uses a manual drain, so collected water is expelled by opening the drain valve during service checks. It is the low-pressure type (code L); its exact regulation range is not published in the material we hold, so confirm your set pressure with us before ordering. No gauge is fitted, a reverse/check valve is fitted, and a mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, in PT (the catalogue standard), G and NPT threads, with manual, automatic or differential-pressure drains, 40 um or 5 um elements, gauge options and an optional reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Rated flow is published as curves rather than a single figure, so ask us to confirm flow and datasheet details for your application.
| Model | GFR200C06MLNWTK AirTAC Filter Regulator 1/8 in NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding spray guns on a low-pressure finishing line: the 5 um element strips water and particulate before the gun while the low-pressure regulator holds the modest set pressure the finish calls for, and the manual drain is emptied at each shift check.
Supplying compact pick-and-place cylinders and small grippers on an electronics assembly bench, where the 1/8 in port matches the machine's small-diameter air lines and the check valve holds the circuit against backflow.
Providing clean, low-pressure regulated air to benchtop analytical and test instruments, where the 5 um grade protects sensitive internal pneumatics from moisture and particles and the bracket secures the unit inside the instrument cabinet.
The real choices on this family are the size and port step, the drain type, the filter grade, the gauge and the thread. This code fixes them at size 200 with a 1/8 in NPT port, a 5 um element, a manual drain, the low-pressure regulator type, no gauge, a fitted check valve and an included bracket. Choose size 200 with a 1/8 in port where the circuit's air demand is small; step up through 300, 400 and 600 for larger ports and more flow. Pick the 5 um element where downstream equipment needs finer filtration than the 40 um standard. Choose a manual drain where the unit is serviced routinely, an automatic drain where unattended water removal matters, or the differential-pressure default. Threads come as PT (the catalogue standard), with G and NPT as order options. Flow is published as curves, not a single rating, so send us your application's air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves, not as a single rated figure, so we do not quote a number here. Tell us your inlet pressure, set pressure and air demand, and we will confirm the flow for this exact model from the datasheet before you order.
The code M sets a manual drain: open the drain valve to expel collected water during routine service. If the unit will run unattended, ask for the automatic-drain version; the catalogue default is differential-pressure drain. The N code means no gauge is fitted, and the low-pressure type's exact regulation range is not published, so confirm your set pressure with us.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.