The AirTAC GFR200C06NTK AirTAC Filter Regulator, NPT1/8, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06NTK is a size-200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a 1/8 in NPT port, 40 um standard filtration, a differential-pressure drain that bleeds condensate automatically whenever the pressure differential across the element is high enough, and a reverse/check valve fitted to hold downstream pressure if the upstream supply drops. No gauge is fitted, so add a separate gauge if you need to read the regulated pressure. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulation range is 0.15-0.9 MPa (20-130 psi), and the operating temperature is -5 to 70 C (non-freezing). The polycarbonate bowl suits this size, and a mounting bracket is included.
This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, an optional 5 um element (code W), optional gauges, and G(BSPP) or NPT threads as order options. Flow for this series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200C06NTK AirTAC Filter Regulator, NPT1/8, 40 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Clean, regulated air for the solenoid valves and I/O manifolds in a machine's control cabinet, with the check valve holding the regulated circuit steady during brief upstream dips.
Feeding a small clamping cylinder or workholding fixture at a set pressure, with 40 um filtration protecting the valve and cylinder seals from water and swarf in shop air.
Conditioning the branch feeding conveyor diverters and small packaging actuators, where the differential-pressure drain keeps condensate moving without daily manual draining.
Size up by port and flow: the 200 size with a 1/8 in port suits compact circuits and low-flow branches; step to 300, 400 or 600 when the line demands more air. Choose the drain to match access: differential-pressure (this unit) needs no attention but only clears condensate when the differential is high enough; automatic drains continuously; manual drains only when someone opens them, which suits periodically attended installations. The 40 um element is the standard choice for general plant air; specify the 5 um W-grade element where finer protection matters. This unit ships without a gauge, so plan an external gauge (round or square, MPa/psi/bar scale) if operators must set or verify pressure. Thread is NPT here; PT is the catalogue standard and G(BSPP) is also available to order, and the mounting bracket is included.
Flow for the GFR series is published as curves, not a single rated number, so send us your application's flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one rated flow number we can honestly quote. Send us your required flow and working pressure and we will confirm the datasheet figures for this exact 1/8 in, size-200 unit on request.
The N in the code means no gauge is supplied, so you read and set the regulated pressure with a separate external gauge (round or square, with an MPa, psi or bar scale) mounted on the unit. If you prefer a gauge fitted as standard, order the GFR200 variant without the N code and we will confirm the available gauge and scale options on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.