The AirTAC GFR200C06NWTK AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06NWTK is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This 200-size unit is threaded NPT1/8 (1/8 in) and carries the 5 um filter element (code W) for finer filtration than the 40 um standard element. It drains by differential pressure, so collected condensate is expelled automatically when the pressure differential across the element rises - no daily manual draining. No gauge is fitted (code N), and a reverse/check valve is built in (code K) to hold downstream pressure if the supply is lost. A mounting bracket is included.
This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge and thread options, and a low-pressure variant. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.
| Model | GFR200C06NWTK AirTAC Filter Regulator NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding a compact bench press or crimping tool: the 5 um element keeps fine particulate out of the cylinder seals while the regulator holds a steady working pressure for repeatable forming strokes.
Supplying air to diverters, pushers and clamp cylinders on a packaging conveyor, where the differential-pressure drain keeps condensate out of the valves without an operator stopping to drain a bowl.
Conditioning air for pick-and-place grippers and small actuator clusters, where the built-in check valve holds the gripper position if the upstream supply drops and the 5 um element protects delicate sealing surfaces.
Size the unit by the flow your line needs: the 200 size with its 1/8 in port is the smallest step in the GFR range - if your demand is near or above its curve limit, step up to GFR300/400/600 with the matching port. This unit already carries the 5 um element; the standard element is 40 um, so choose 5 um only where finer particulate control matters. Drain is differential-pressure here; automatic (A) and manual (M) variants exist if you prefer a different drain behaviour. A gauge can be added (round or square, MPa/psi/bar scales) - this unit ships without one. Thread is NPT here; PT is the standard and G (BSPP) is also an orderable option. Flow for this family is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and the air demand of your equipment and we will confirm from the datasheet whether this 200-size, 1/8 in unit is correctly sized - or whether a 300 or 400 size suits better.
The N in the code means no gauge is fitted. The GFR family accepts a gauge option - an embedded square gauge or an external round gauge, with MPa, psi or bar scales - so if you want a downstream pressure indication, ask for the equivalent code with the gauge position filled before ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.