The AirTAC GFR200C08F2TK AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08F2TK is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This unit is the 200 size with a 1/4 in NPT port, a 40 um standard filter element and a differential-pressure drain. A square embedded gauge on a psi scale is fitted, a reverse (check) valve is built in (code K), and a mounting bracket is included. The polycarbonate bowl suits the 200 size, the standard regulator covers 0.15-0.9 MPa (20-130 psi), and the unit is rated to 1.0 MPa (145 psi) inlet for use in -5 to 70 C non-freezing compressed air.
This is a genuine AirTAC part. The GFR family spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, and options include a 5 um element (code W), automatic or manual drains, G (BSPP) or NPT threads in place of the PT standard, and MPa, psi or bar gauge scales. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GFR200C08F2TK AirTAC Filter Regulator NPT1/4 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding pneumatic clamps, tool-change actuators and air tools on a machining centre, where filtered air at a set regulated pressure keeps fixtures and cylinders working consistently.
Supplying carton tapers, case erectors and bagging heads on a packaging line, with the 40 um element removing water and particulates before they reach the folding and sealing cylinders.
Regulating air to pick-and-place modules and test fixtures in lab automation, where a stable downstream pressure and clean supply protect sensitive motion components.
Choose the size by port and flow: 200 carries a 1/4 in port here, with 300, 400 and 600 stepping up in port and capacity. Drain options are differential-pressure (this unit), automatic (A) or manual (M); the 40 um element is standard and 5 um (W) is available where finer filtration is needed. Gauge scales come in MPa, psi or bar - this unit reads psi - and threads can be ordered in G (BSPP) or NPT instead of the PT standard. Flow for the GFR series is published as curves, not a single rating, so send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one number we can quote honestly. Tell us your required flow and working pressure and we will confirm the figures from the datasheet on request.
The 40 um element is standard and suits general plant air; the W variant gives 5 um filtration where finer protection is needed. This unit carries the standard 40 um grade, and its differential-pressure drain is the series' standard drain option, with automatic (A) and manual (M) drains available to order.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.