The AirTAC GFR200C08F2WT AirTAC Filter Regulator NPT1/4 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08F2WT is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 200-size unit is fitted with a 1/4 in NPT port, a 5 um filter element (the finer of the two available grades), a differential-pressure drain that bleeds collected condensate automatically whenever the pressure drop across the element is high enough, and an embedded square gauge reading in psi. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), a mounting bracket is included, and no reverse/check valve is fitted.
This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with choices of drain type, filter grade, gauge style and scale, thread form and bracket. Flow figures for this family are published as curves rather than a single rating, so if you need a specific flow or any other datasheet figure for the GFR200C08F2WT, ask us and we will confirm it against the AirTAC datasheet before you order.
| Model | GFR200C08F2WT AirTAC Filter Regulator NPT1/4 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, regulated air to the tool-clamp and air-blast circuits of a CNC machining centre, where the 5 um element helps keep moisture and chips-borne contamination out of clamping valves and the square psi gauge lets setters verify set pressure at a glance.
Installed at the air drop feeding the cylinders and diverters on a carton packaging conveyor, providing one clean, regulated supply point per station with the differential-pressure drain handling condensate build-up through the shift.
Used on the air line serving spray guns and air-assisted applicators in a paint booth, where the 5 um grade and stable regulated pressure support consistent atomisation and the included bracket allows tidy panel mounting beside the booth.
Start with the port and body size: the 200 series with a 1/4 in NPT port suits compact drops and individual machines, while 300, 400 and 600 sizes step up in port and flow capacity - match the step to the air demand of the circuit rather than oversizing blindly. Next choose the drain: this unit uses the differential-pressure drain (the default), but automatic and manual drains are available in the family if your installation needs them. On filtration, 40 um is the standard element and 5 um (code W, fitted here) is the finer option for downstream equipment that needs cleaner air. Gauge options cover embedded square or external round bodies with MPa, psi or bar scales - this unit carries a square psi gauge. Thread is PT as the AirTAC standard, with G (BSPP) and NPT as order options; this unit is specified in NPT. A bracket is included on this configuration. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the AirTAC datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as performance curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Tell us your application and operating pressure and we will confirm the flow behaviour from the AirTAC datasheet on request before you order.
The W code in GFR200C08F2WT selects the optional 5 um element; the family default is 40 um, so choose the 5 um grade when downstream equipment needs finer filtration. This unit uses the differential-pressure drain (the default): it discharges collected condensate automatically when the pressure drop across the element rises, with no manual draining needed, and automatic or manual drains are available as alternatives in the family.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.