The AirTAC GFR200C08JC2GK AirTAC Filter Regulator G1/4, psi Gauge is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08JC2GK is an AirTAC GFR200 series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This configuration has G1/4 (1/4 in) ports with G (BSPP) thread, 40 um standard filtration, a differential-pressure drain that bleeds condensate automatically whenever the pressure differential across the element is high enough, and a fitted reverse/check valve that holds the downstream setting if upstream pressure is lost. Outlet pressure is set across the standard 0.15-0.9 MPa (20-130 psi) adjustment range, and the round external gauge reads in psi so operators can check the setting at a glance. It is supplied without a mounting bracket.
This is a genuine AirTAC part from the G-series air-treatment line, which spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, thread options PT (standard), G and NPT, manual, automatic or differential-pressure drains, and an optional 5 um filter element (code W). Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C08JC2GK AirTAC Filter Regulator G1/4, psi Gauge |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding clean, regulated air to the tool-change clamps and pneumatic cylinders on a machining centre, with the check valve holding the clamp setting if shop supply dips.
Conditioning the air that drives conveyor stop-gates, baggers and carton-sealing cylinders, where the 40 um element keeps debris out of the control valves.
A point-of-use filter regulator at an assembly bench, giving each operator a stable, locally adjustable pressure for air tools and small pneumatic presses.
Start with the port step: this unit is size 200 with G1/4 ports, the entry size of the GFR range - if your line draws more air, the same function is available in sizes 300, 400 and 600 with larger ports, so match the size to the flow your circuit needs rather than to the pipe alone. The drain here is differential-pressure, which suits panels that stay pressurised; choose automatic drain (code A) for unattended duty or manual drain (code M) where you want to purge on demand. Filtration is the standard 40 um element, which protects most actuators and valves; specify the 5 um W grade if downstream equipment needs finer protection. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are the other catalogue choices. Thread is G (BSPP) here, with PT (the series standard) and NPT available to order, and the J code means no mounting bracket is included - order one if the unit will not be panel- or manifold-mounted. Because AirTAC publishes flow only as curves, not as a single rating, ask us to confirm sizing against your application before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the datasheet and check the sizing for you before you order.
The differential-pressure drain is the catalogue default: it expels collected condensate automatically when the pressure differential across the filter element rises, with no operator input. If your duty is unattended or intermittent, the same GFR200 body is available with an automatic drain (code A) or a manual drain (code M) - ask us for those variants.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.