The AirTAC GFR200C08JC2K AirTAC Filter Regulator 1/4 in PT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08JC2K is a filter regulator: it removes water and particulate from compressed air and sets downstream pressure in a single body. This size 200 unit has a PT1/4 (1/4 in) port with PT thread, a 40 um standard filter element, and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough. The fitted round gauge reads in psi, and the built-in check valve (code K) lets downstream air pass back through the unit on exhaust so the circuit can vent through it. The standard regulator covers 0.15-0.9 MPa (20-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi), and the unit works from -5 to 70 C in non-freezing conditions. No mounting bracket is included with this code.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 40 um or 5 um (W) element, embedded square or external round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads as order options. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C08JC2K AirTAC Filter Regulator 1/4 in PT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds a workholding clamp circuit on a machining cell, cleaning the supply and holding a set clamping pressure so parts stay gripped through the cycle; the check valve lets the circuit vent back through the unit.
Sits at the drop of a cartoning or wrapping line to strip water and debris from the plant air and set a stable pressure for the machine's cylinders and seal bars, with the psi gauge read at a glance by operators.
Prepares air for the stop-and-divert cylinders along a sortation conveyor, keeping moisture out of the valves and letting maintenance set the gate pressure locally without touching the main supply regulator.
Step up through the GFR sizes (200, 300, 400, 600) and their ports (1/8 in to 1 in) to match the air demand of the circuit; the port step follows the size, so pick the size whose flow curve covers your consumption with margin. Choose the drain to suit access: differential-pressure (this unit) needs no attention, automatic drains on a timer-free basis, and manual suits supervised points. Pick the 40 um standard element for general air preparation or the 5 um (W) element for finer protection, and select the gauge scale your team reads - this code carries a round psi gauge. Thread is PT as standard with G (BSPP) and NPT as orderable options, and brackets are optional (this code omits one).
Because flow is published as curves rather than a single rating, send us your application details and we will confirm the datasheet figures and correct sizing before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so there is no one rated flow number we can quote. Send us your line pressure and air consumption and we will confirm the datasheet curve and check the sizing for your application before you order.
K means a reverse (check) valve is fitted, so downstream air can flow back through the unit when the circuit exhausts. This unit's drain is differential-pressure type: condensate collected in the polycarbonate bowl is bled off automatically when the pressure differential across the 40 um element rises, so no manual draining routine is needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.