The AirTAC GFR200C08JC3WTK AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08JC3WTK is a GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a 1/4 in NPT port, a differential-pressure drain, a 5 um filter element (code W), a round gauge with bar scale, and a built-in reverse (check) valve; no mounting bracket is fitted. Maximum inlet pressure is 1.0 MPa (145 psi), the regulation range is 0.15-0.9 MPa (20-130 psi), the working temperature range is -5 to 70 C (non-freezing), and the bowl on this 200 size is polycarbonate (PC).
This is a genuine AirTAC part from the GFR200 size family, one of four sizes (200/300/400/600) with ports from 1/8 to 1 in and PT, G or NPT threads available across the series. Filter grade, drain type, gauge style and scale, and check valve are all selectable options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GFR200C08JC3WTK AirTAC Filter Regulator NPT1/4 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feed the pneumatic cylinders on a carton-sealing machine with clean, regulated air at a set pressure, while the built-in check valve helps hold the downstream circuit if the upstream supply dips.
Provide point-of-use filtration and regulation for a small bench press, with the 5 um element protecting the directional valve and cylinder seals from finer contamination.
Supply regulated air to pick-and-place grippers on a laboratory automation skid, where the round bar-scale gauge matches the instrument-style readouts used on the panel.
Pick the size and port step (200 through 600, 1/8 to 1 in) against the air demand of your circuit; this unit is the 200 size with a 1/4 in NPT port. The filter element here is 5 um (code W) instead of the standard 40 um, which suits downstream equipment sensitive to finer particles. The differential-pressure drain is the default: it discharges condensate automatically as the pressure differential across the element builds, with automatic and manual drain variants available elsewhere in the series. Gauge style and scale (embedded square or external round; MPa, psi or bar), PT vs G/NPT thread, bracket and check valve are all order choices. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
Flow for the GFR200 is published as curves rather than a single rated figure, so we do not quote one number. Tell us your application and we will confirm the datasheet flow curve and correct sizing before you order.
K means a reverse (check) valve is fitted: air flows one way through the unit, which helps hold the regulated downstream pressure if the upstream supply is interrupted. Configurations without the K code have no check valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.