The AirTAC GFR200C08JF2 AirTAC Filter Regulator 1/4 in PT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08JF2 is a size-200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration carries a 1/4 in PT port, the standard 40 um filtration grade, a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and an embedded square gauge reading in psi. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, and no mounting bracket or reverse/check valve is fitted on this code.
This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with a choice of ports and G (BSPP) or NPT thread options, manual or automatic drains, a 5 um (code W) element, and MPa, psi or bar gauge scales. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application.
| Model | GFR200C08JF2 AirTAC Filter Regulator 1/4 in PT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding clamp and hold-down cylinders on a small assembly press: the 40 um element keeps scale and pipe debris out of the cylinders while the regulator holds a steady clamp pressure on a 1/4 in PT drop.
Conditioning the air feed to bench instruments and small pneumatic test rigs, where the square psi gauge gives a clear local setpoint readout and the differential-pressure drain keeps condensate off the bench without daily attention.
Supplying diverters, stoppers and small actuators along a packaging conveyor line, with the filter-regulator set at the drop point so each section runs at its own regulated pressure off the 1/4 in PT takeoff.
Start with the port step: size 200 with a 1/4 in PT port suits lines plumbed at 1/4 in; step up to GFR300/400/600 when the circuit calls for larger ports and higher flow. Choose the drain next: this unit's differential-pressure drain needs no operator attention, while a manual drain (code M) suits positions you already walk past, and an automatic drain (code A) suits unattended duty. The 40 um element is the standard grade; specify 5 um (code W) only where finer particulate control matters. This code ships with the embedded square gauge in psi; MPa and bar scales and an external round gauge are order options. PT is the standard thread; G (BSPP) and NPT are catalogue options to order. A mounting bracket is optional and not fitted on this code.
Because flow is published as curves rather than a single rating, we cannot quote one number here - send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your application and line pressure and we will confirm the flow data from the datasheet on request before you order.
This code carries the differential-pressure drain, the GFR default: condensate collected in the bowl is bled off automatically as air flows through, with no operator input. If your installation would suit a manual drain (code M) or a fully automatic drain (code A), those are catalogue options on the same size - just ask us for the alternative model code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.