The AirTAC GFR200C08JF2K AirTAC Filter Regulator 1/4 in PT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08JF2K is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and holds downstream pressure at your setpoint in a single body. This configuration is the size 200 unit with a PT1/4 (1/4 in) port, 40 um standard filtration element, differential-pressure drain and a PC (polycarbonate) bowl. The embedded square gauge reads in psi, and a reverse/check valve is fitted so the set pressure is not lost back through the unit if the upstream supply dips. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulation range is 0.15-0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options include 5 um (W) filtration, automatic or manual drains, alternative gauge scales (MPa/psi/bar), G (BSPP) or NPT threads, and bracket choices. Flow figures are published as curves rather than a single rating, so ask us to confirm datasheet figures for your application before ordering.
| Model | GFR200C08JF2K AirTAC Filter Regulator 1/4 in PT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding pneumatic clamps and tool-change cylinders on a machining centre: the 40 um element keeps water and particles out of the valve stack while the regulator holds the set pressure and the check valve guards it against upstream dips.
Supplying sample-handling valves and small pneumatic actuators on lab analysers that need clean, regulated air at a fixed psi, readable at a glance on the square gauge.
Point-of-use air prep for pick-and-place cylinders and product diverters on a packaging conveyor, with the 1/4 in PT port matching typical machine drops.
Size 200 with a 1/4 in port is the small step of the GFR range; move up to 300, 400 or 600 when your line needs a larger port and more flow capacity. The differential-pressure drain (the default here) discharges condensate as the pressure drop across the element builds; if your duty is very low-flow, ask about the automatic (A) or manual (M) drain variants. The 40 um element suits general plant air, and the W option gives 5 um where downstream equipment needs finer filtration. This configuration includes the embedded square gauge scaled in psi; external round gauges and MPa or bar scales are alternatives. Thread is PT as standard, with G (BSPP) and NPT as order options, and the J code means no mounting bracket is included - a bracket can be ordered. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and datasheet figures for this exact unit on request.
It means a reverse/check valve is fitted. The valve prevents reverse flow through the unit when upstream pressure falls below the downstream set pressure, which is useful on circuits where a momentary supply dip must not release a clamp or actuator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.