The AirTAC GFR200C08JF2WGK AirTAC Filter Regulator G1/4, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08JF2WGK is an AirTAC GFR200 filter regulator: a single body that removes water and particulate from compressed air and regulates downstream pressure. This configuration is the size 200 unit with a G1/4 (BSPP) port, 5 um filtration (the finer of the two catalogue grades), a differential-pressure drain, and a PC (polycarbonate) bowl. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), a fitted square gauge reads in psi, and a reverse/check valve is built in. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. No mounting bracket is included with this code.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with a choice of port sizes, PT, G or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um filtration, and gauge scale options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C08JF2WGK AirTAC Filter Regulator G1/4, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Clean, regulated air feeding tool-changer and clamping circuits on a machining centre, with the 5 um element guarding fine pneumatic components from water and particulate carryover.
Filtering and regulating the air feeding cylinders and diverters along a carton packaging conveyor, with the check valve holding the set circuit against backflow.
Conditioning supply air for benchtop laboratory automation and sample-handling pneumatics, where the psi-reading square gauge gives operators a direct setpoint check at the panel.
Start with the port step: size 200 with a G1/4 port suits lighter air-preparation duty, and larger sizes (300, 400, 600) step up port and body size as your demand grows. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. Other decodable choices on this family: drain type (differential-pressure as on this unit, automatic, or manual), filter grade (40 um standard, 5 um as coded here with W), gauge scale (MPa, psi or bar, embedded square or optional external round), thread (PT is the standard, G and NPT are order options), and whether a mounting bracket is fitted.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so no single number is quoted here. Contact us and we will confirm the flow curves and datasheet figures for this exact model against your application before you order.
The W in the model code selects the 5 um element, the finer of the two catalogue grades (40 um is the standard). Choose 5 um where downstream valves, cylinders or instruments need finer protection; the differential-pressure drain and all other functions of this filter regulator are unchanged.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.