The AirTAC GFR200C08JF2WT AirTAC Filter Regulator NPT1/4, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08JF2WT is a 200-size filter regulator that removes water and particulate from compressed air and holds downstream pressure in one body. This configuration is threaded NPT1/4 (1/4 in), carries the finer 5 um filter element (the 40 um element is the standard option), drains condensate by differential pressure, and has an embedded square gauge reading in psi. The standard-type regulator adjusts from 0.15-0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this 200 size is polycarbonate (PC); no mounting bracket is included with the J suffix.
This is a genuine AirTAC part in the GFR filter-regulator family, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in. Across the range you can order manual or automatic drain instead of the differential-pressure drain, the 40 um or 5 um element, a square or external round gauge with MPa, psi or bar scales, a reverse/check valve, and PT, G (BSPP) or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GFR200C08JF2WT AirTAC Filter Regulator NPT1/4, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use supply for carton-sealing and case-erector cylinders: the 5 um element protects directional valves from water and fine particulate while the regulator holds a steady working pressure for consistent jaw and pusher action.
Conditioned air for sample-handling actuators and pneumatic grippers on analytical benches, where the finer 5 um grade and a stable regulated pressure keep sensitive components clean and repeatable.
A regulated, filtered drop at each service bay feeding impact wrenches and air ratchets, with the square psi gauge letting technicians set and check tool pressure at a glance.
Start with the port step: 200 size covers 1/8 in and 1/4 in, and the 300/400/600 bodies step up through 3/8 in, 1/2 in, 3/4 in and 1 in as your air demand grows - match the size to the flow your circuit needs rather than to the pipe alone. Choose the drain next: differential-pressure drain (this unit) bleeds condensate as the pressure drop across the element rises, while automatic drain suits unattended installations and manual drain suits periodically attended points. Pick the element grade: 40 um is the standard general-purpose grade and 5 um (this unit, code W) is the finer grade for sensitive downstream valves and instruments. Then set the gauge - embedded square is standard with MPa, psi or bar scales, and an external round gauge is optional - and the thread: PT is the standard, with G (BSPP) and NPT ordered as options. Brackets are optional on GFR units; this J-suffix model comes without one. Because flow is published as curves and not as a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote one number here. Tell us your line pressure, set pressure and air demand and we will confirm the flow from the datasheet curves for this exact model on request before you order.
The W in the code selects the finer 5 um element instead of the 40 um standard grade, which suits downstream valves, cylinders and instruments that need cleaner air. With no drain letter in the code, the bowl uses the differential-pressure drain, which discharges condensate as the pressure drop across the element rises; automatic (A) and manual (M) drains are available as order options.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.