The AirTAC GFR200C08JF3T AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08JF3T is a filter regulator: water and particulate removal plus pressure regulation combined in a single body, for compressed air only. This size 200 unit is specified with 1/4 in NPT ports, the standard 40 um filter element, a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and a fitted square gauge reading in bar. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi) with this drain type, maximum inlet pressure is 1.0 MPa (145 psi), the operating temperature range is -5 to 70 C (non-freezing), the bowl is polycarbonate, and no mounting bracket or reverse/check valve is fitted.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in. Related configurations offer a 5 um element (code W), automatic or manual drains, PT or G thread options, and gauge scales in MPa, psi or bar. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | GFR200C08JF3T AirTAC Filter Regulator NPT1/4 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Conditioning the air supply to a bench-top pneumatic press: the 40 um element stops particulate reaching the cylinder valves while the regulator holds the set working pressure for consistent forming and staking strokes.
Supplying cleaned, pressure-controlled air to the tape-head and flap-fold cylinders of a carton sealer, where the differential-pressure drain keeps condensate out of the valve stack without daily manual draining.
Feeding the gripper and rotary-actuator circuit of a pick-and-place module, with the bar-scale square gauge giving operators a local setpoint readout at the machine's air preparation point.
Start with the port step: this unit is the size 200 body with 1/4 in NPT ports; larger sizes (300/400/600) step up in port and capacity, so match the size to the air demand of the circuit. Choose the drain to suit access: this configuration uses the differential-pressure drain, while automatic (code A) and manual (code M) versions exist. The 40 um element is the standard grade; specify 5 um (code W) where finer particulate removal is needed. The fitted square gauge here reads in bar, and MPa or psi scales are alternatives; PT (standard) and G threads are order options alongside this NPT version, and a bracket can be added where this no-bracket configuration needs panel fixing. Because flow is published as curves and not as a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so no rated flow number is quoted here. Tell us your application and we will confirm the relevant flow and datasheet figures on request before you order.
With no drain code in the model, the differential-pressure drain is fitted: it bleeds collected condensate automatically as air flows through, with the regulator adjustment range of 0.15-0.9 MPa (20-130 psi). If you prefer an automatic (code A) or manual (code M) drain, those variants exist in the same series and we can confirm the right configuration on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.