The AirTAC GFR200C08LC1T AirTAC Filter Regulator NPT1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08LC1T is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation combined in a single 200-size body. This configuration has 1/4 in NPT ports, the standard 40 um filter element, a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and a round pressure gauge with an MPa scale so the setpoint can be read and adjusted at the unit. It is the low-pressure (L) regulator type, intended for circuits that run at reduced supply pressure rather than full line pressure.
This is a genuine AirTAC part. The GFR family is published in 200, 300, 400 and 600 sizes with port options from 1/8 in to 1 in and PT, G or NPT threads, with manual or automatic drains, a 5 um (W) filter element, gauge and scale choices, and a reverse/check valve available as options. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application before ordering.
| Model | GFR200C08LC1T AirTAC Filter Regulator NPT1/4 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds a fixture-clamp circuit that holds workpieces at a reduced, steady pressure below the main header line, with the 40 um element keeping pipe scale and moisture out of the clamp cylinders.
Mounted at the drop to a packaging machine's small cylinders and actuators, filtering the shop air and regulating it down to the pressure the machine's valve bank is set up for, with the MPa gauge giving the setter a local readout.
Provides filtered, regulated air to benchtop or pilot equipment that runs on a gentler supply than the plant header delivers, with the low-pressure regulator type and differential-pressure drain suited to a continuous, unattended supply.
Size the unit by the flow your line needs at the regulated pressure: step up from 200 to 300, 400 or 600 when the port and flow demand grow - this 200-size unit carries 1/4 in NPT ports. The differential-pressure drain suits a steady, continuous air supply; choose a manual drain (M) for intermittent duty or an automatic drain (A) where condensate load is high. The standard element is 40 um; specify the W option for 5 um filtration where downstream equipment needs finer protection. This unit is the low-pressure (L) regulator type - confirm its adjustment range against your setpoint with us before ordering. Gauge scale (MPa, psi or bar), PT versus G/NPT thread, and the included mounting bracket round out the decodable choices. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your port size, upstream pressure and the flow your application needs, and we will confirm the sizing from the datasheet curves before you order.
The embedded square gauge is the standard fitting; the C1 in this code specifies the optional external round gauge with an MPa scale, which is what is supplied here. The L in the code marks the low-pressure regulator type, intended for circuits regulated below full line pressure - ask us to confirm its exact adjustment range for your setpoint.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.