The AirTAC GFR200C08LC2 AirTAC Filter Regulator 1/4 in PT, Low Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08LC2 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 200 unit has a 1/4 in PT port, the standard 40 um filter element, a differential-pressure drain, and an external round pressure gauge scaled in psi. It is the low-pressure type, selected for circuits that call for regulation below the standard range, and it is rated for a maximum inlet pressure of 1.0 MPa (145 psi) at -5 to 70 C (non-freezing). A mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, drain choices (differential-pressure, automatic or manual), an optional 5 um element (code W), gauge and thread options, and standard or low-pressure regulator types. Flow is published as curves rather than a single rating, so we confirm sizing and datasheet figures on request.
| Model | GFR200C08LC2 AirTAC Filter Regulator 1/4 in PT, Low Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Clean, regulated air to a bench pneumatic press or arbor press cylinder, with the low-pressure type holding a gentle set point for forming, staking and light assembly work.
Point-of-use air prep for conveyor diverters and packaging actuators, where the 40 um element keeps water and debris out of directional valves and the round psi gauge gives a local reading.
Regulated air for laboratory automation manifolds and small test rigs, where a compact 1/4 in filter regulator with a psi-scaled gauge keeps instruments fed with clean, stable air.
Size and port step up together with flow demand: this 200 unit takes a 1/4 in port, while 300, 400 and 600 sizes move up to 1 in. Choose the drain to match service - differential-pressure (as on this unit) drains as the pressure differential builds, automatic suits unattended duty, and manual gives the operator direct control. The 40 um element is standard; specify code W for 5 um when finer filtration is needed. Gauge scale (MPa, psi or bar), thread (PT standard; G or NPT as order options) and the bracket are all decodable choices. Because AirTAC publishes flow as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow curve and correct sizing from the datasheet on request.
The C2 code in GFR200C08LC2 specifies the external round gauge scaled in psi; the embedded square gauge is the standard fitting on GFR units. MPa, psi and bar scales are catalogue options, so order the code that matches your panel and local reading preference.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.