AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um

The AirTAC GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$41.70 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um

The AirTAC GFR200C08LF2W is a size-200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a PT1/4 (1/4 in) port, a fine 5 um filter element (code W), a differential-pressure drain that bleeds collected condensate whenever the pressure drop across the element rises, and the low-pressure regulator type for circuits set well below standard line pressure. An embedded square gauge reading in psi is fitted so the setpoint can be watched directly, a mounting bracket is included, and the unit carries a metal bowl.

This is a genuine AirTAC part from the GFR range, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um fine filtration, square or round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow figures are published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.

GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um Technical Specifications

ModelGFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um Is Used

valve

Low-pressure pneumatic clamping on packaging machinery

On a carton-sealing or case-packing line, low-pressure air holds products gently in clamping fixtures. This unit filters the supply to 5 um and holds the reduced pressure the clamp cylinders were sized for, with the psi gauge letting a technician verify the setting at the machine.

air

Air preparation for spray-painting guns in a finishing booth

Paint spray guns and air-assisted applicators are spoiled by water and fine particles in the supply. Feeding the gun line through this filter regulator removes moisture and 5 um particulate and sets the lower atomising pressure the finish calls for.

conveyor_belt

Pneumatic diverters and stoppers on a conveyor line

Sorting and accumulation conveyors use air cylinders to divert, stop and lift product. This unit cleans the branch supply, regulates it to the pressure those cylinders need, and its differential-pressure drain keeps condensate from accumulating in the bowl during continuous shifts.

Is the GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um the Right Unit?

Start with the port and size: this unit steps at 1/4 in PT in size 200, so match it to the line size your air travels on and check the flow curve against what the circuit actually consumes - we can confirm the curve figures on request before you order. Because this is the low-pressure type, it suits circuits whose setpoint sits well below normal working pressure; if your setpoint is higher, ask us to check the standard-type GFR200 variant instead. The 5 um element (code W) is the right choice where finer particulate matters; the 40 um standard element is the default for general shop air. The differential-pressure drain is automatic in operation and needs no daily attention; automatic-float and manual-drain versions exist if your duty differs. The fitted square gauge reads in psi; MPa and bar scales and an external round gauge are alternatives. PT thread is the standard here - G (BSPP) and NPT are order options - and a bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Send us your line pressure, setpoint and the air consumption of the equipment you are feeding, and we will confirm the flow-curve figures from the datasheet on request before you order.

The W in the code specifies the fine 5 um element, suited to applications such as spraying, instrumentation and sensitive cylinders where finer particulate must be removed. The 40 um element is the standard grade for general shop air and is available on the equivalent GFR200 configuration - choose 5 um when the downstream equipment demands cleaner air, otherwise the standard grade is the economical default.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C08LF2W AirTAC Filter Regulator PT1/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C08LF2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.