The AirTAC GFR200C08LF2WT AirTAC Filter Regulator NPT1/4 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08LF2WT is an AirTAC GFR-series filter regulator: one body that removes water and particulate from compressed air and holds downstream pressure at a set point. This unit is the 200 size with a 1/4 in NPT port, fitted with the finer 5 um filter element (the W grade; 40 um is the standard option), a differential-pressure drain, a low-pressure regulator, and an embedded square gauge reading in psi. A mounting bracket is included, the polycarbonate bowl suits non-freezing air from -5 to 70 C, and maximum inlet pressure is 1.0 MPa (145 psi).
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, and options include automatic or manual drains, the 40 um or 5 um element, square or round gauges with MPa, psi or bar scales, G or NPT threads in place of the PT standard, and a reverse/check valve. AirTAC publishes flow for this family as curves rather than a single rated figure, so ask us to confirm sizing or any datasheet figure for your application.
| Model | GFR200C08LF2WT AirTAC Filter Regulator NPT1/4 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding a small pneumatic press or clamping fixture: the 5 um element keeps sludge and scale out of the valve and cylinder, while the low-pressure regulator holds the working pressure the tooling was set up for.
On a packaging or labelling line, the filter stage strips water condensed in the ring main before it reaches the actuators, and the regulator keeps gripper and sealing cylinders running at a steady set point.
Where a spray, coating or glue application calls for a lower regulated pressure than a standard regulator range, this low-pressure type lets the line run at its set point on clean, dried air.
Choose the size and port against the flow your line needs: 200 is the compact step with a 1/4 in port here, and the larger 300/400/600 sizes carry bigger ports and more flow - we can confirm the curve for your consumption. Pick the drain: differential-pressure (this unit) empties the bowl on a pressure swing, automatic drains continuously, and manual drains need a routine twist. This unit carries the finer 5 um element where downstream valves and instruments need cleaner air than the standard 40 um grade. The embedded square gauge reads psi; round gauges and MPa or bar scales are options. Thread is NPT here; PT is the AirTAC standard and G (BSPP) is also orderable. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves rather than a single rated number, so we do not quote a figure here. Send us your line pressure and air consumption and we will confirm the flow from the datasheet for this 200-size, 1/4 in unit before you order.
The W code selects the finer 5 um element instead of the standard 40 um grade - the right choice ahead of valves, cylinders or instruments that need cleaner air. The drain is differential-pressure: the bowl empties automatically whenever the pressure drop across the element builds, with no manual routine. Automatic and manual drains are orderable alternatives.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.