The AirTAC GFR200C08LJC2 AirTAC Filter Regulator 1/4 PT Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08LJC2 is an AirTAC GFR200 filter regulator: filtration and pressure regulation combined in a single body. It removes water and particulate from compressed air at the standard 40 um grade while regulating downstream pressure, and the low-pressure type code (L) means it is built for circuits set below the standard regulator range. This configuration has a 1/4 in PT port, a differential-pressure drain that bleeds accumulated condensate automatically as flow passes through, and an external round gauge fitted on the psi scale. No mounting bracket is included with this code.
This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with a choice of ports, threads (PT standard, G and NPT to order), drain types, 40 um or 5 um filtration, gauge styles and scales, and standard or low-pressure regulation. Flow figures are published as curves rather than a single rating, so ask us to confirm sizing and datasheet details for your application before ordering.
| Model | GFR200C08LJC2 AirTAC Filter Regulator 1/4 PT Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a packaging line where sealing bars or clamp actuators are specified for a lower supply pressure than the main header, this low-pressure filter regulator cleans the air and holds a reduced, stable setting at each 1/4 in take-off point.
A compact pick-and-place cell fed from the shop air main needs water and particle removal plus a reduced setting for its gripper valves. This unit does both jobs in one body at a single 1/4 in connection, saving panel space.
At a lab or test bench where instruments and small air tools run on cleaned air at a modest, fixed pressure, the 40 um filter protects the equipment and the psi-scale round gauge lets the operator read the setting at a glance.
Size and port step up together: 200 through 600 covers larger ports and more flow, so pick the size whose flow curve covers your demand at the working pressure - we will check the curve with you. Where a bowl is fitted you choose the drain: differential-pressure (this unit, self-acting with flow), automatic, or manual. Filtration is 40 um standard; choose code W for 5 um where finer particulate removal is needed. The gauge on this unit is the external round type reading in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. Thread is PT as standard, with G (BSPP) and NPT available to order, and a bracket can be added if this J-coded (no-bracket) version needs panel mounting. Because flow is published as curves and not a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your working pressure and air demand and we will confirm the sizing from the datasheet curves before you order.
The differential-pressure drain is the default bowl drain: condensate collected in the bowl is bled off automatically as air flows through, with no manual action needed. The C2 code means an external round gauge is fitted reading in psi; an embedded square gauge, or MPa or bar scales, are the alternative catalogue options.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.