The AirTAC GFR200C08LJC2G AirTAC Filter Regulator G1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08LJC2G is an AirTAC GFR200 filter regulator: water and particulate filtration plus pressure regulation combined in one body. This configuration has a G1/4 (1/4 in) port, the low-pressure regulator type, a 40 um filter element and a differential-pressure drain, and it is fitted with a round gauge reading in psi. A check valve is not fitted and no mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the GFR series, which spans sizes 200 to 600 with ports from 1/8 to 1 in, drain choices (differential-pressure, automatic or manual), an optional 5 um element (code W) and gauge, thread and bracket options to order. Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR200C08LJC2G AirTAC Filter Regulator G1/4 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, low-pressure regulated air feeding the spray guns in an automotive refinishing booth, with water and pipe-scale particles removed before they reach the finish.
Conditioned air supply for the vacuum ejectors and small cylinders on an electronics assembly gantry, with the psi gauge letting technicians verify set pressure at the cell.
Low-pressure regulated supply to the clamping cylinders on a machining fixture, keeping the clamp circuit stable while the 40 um element protects the valve seats.
Start with the port: this unit is a size 200 with a G1/4 connection, one step in a GFR range that runs from 1/8 to 1 in across sizes 200-600, so match the size step to the air demand of the circuit. This is the low-pressure regulator type, intended for circuits regulated below standard pressures; the exact adjustment range for the low-pressure type is not published, so confirm it with us before ordering. The 40 um element is the standard grade, with a 5 um element (code W) available where finer filtration is needed.
The drain here is the differential-pressure type, which clears the bowl as system pressure drops at shutdown; automatic (A) and manual (M) drains can be ordered instead. The fitted round gauge reads in psi, while embedded square gauges and MPa or bar scales are alternatives. The G (BSPP) thread is an order option - PT is the standard thread and NPT is also available. No mounting bracket is included, but brackets can be ordered. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and datasheet figures for this 1/4 in, low-pressure unit on request.
L marks the low-pressure regulator type, J means no mounting bracket is fitted, C2 is the round gauge with a psi scale, and G is the G (BSPP) thread option. The drain is the differential-pressure type and the filter element is the standard 40 um grade.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.