The AirTAC GFR200C08LJC2T AirTAC Low-Pressure Filter Regulator 1/4 NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08LJC2T is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This size 200 unit is supplied with a 1/4 in NPT port, a 40 um filter element, a differential-pressure drain that bleeds accumulated condensate automatically as air flows, a round psi gauge, and the low-pressure regulator type for circuits that hold a low downstream setting. The polycarbonate bowl suits standard shop-air duty, and this configuration is supplied without a mounting bracket.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, drain choices (differential-pressure, automatic or manual), an optional 5 um element (code W), gauge and scale options, and PT, G or NPT threads as order options. Flow for this family is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200C08LJC2T AirTAC Low-Pressure Filter Regulator 1/4 NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Supplies filtered, low-pressure regulated air to the spray guns on a tablet-coating line, where the coating solution is atomised at a gentle, stable setting and the 40 um element keeps the air clean.
Feeds the sealing jaws and hold-down cylinders on a tray-sealing line, combining water and particle removal with a low regulated setting so delicate packs are not crushed.
Conditions the air feeding spray guns in a finishing booth: the bowl drops out water, the 40 um element traps particles, and the low-pressure regulator holds a gentle atomising setting.
Size and port step up together: 200 with 1/4 in NPT here, then 300, 400 and 600 as your air demand grows - match the step to the circuit. Where a bowl is fitted you choose the drain: differential-pressure (this unit, no operator action), automatic, or manual for controlled blowdown. Filter grade is 40 um standard; specify W for 5 um where downstream equipment needs finer air. Gauge options are an embedded square gauge or an external round gauge with MPa, psi or bar scale - this unit carries a round psi gauge. Thread is NPT here; PT is the standard and G is also an order option. Flow is published as curves, not a single rating, so send us your air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves rather than a single rated figure, so we do not quote a number here. Tell us your air demand and operating pressure and we will confirm the datasheet curve and the correct size for your application on request.
The L code makes this GFR200 the low-pressure regulator type, intended for circuits that hold a low downstream setting; the exact adjustment range for this variant is not published in the catalogue, and we will confirm it on request. The differential-pressure drain then bleeds accumulated condensate automatically as air flows, with no manual blowdown needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.